Diagnostic / Cyclic Configuration / Command Section; Table 11. Supported Default Calibration Types - Renesas ZSSC324 Series User Manual

Hide thumbs Also See for ZSSC324 Series:
Table of Contents

Advertisement

Table 11. Supported Default Calibration Types

Type
2 Point
3 Point
B(O+G + SOT)
4 Point
B(O+G +TC(O+G) T(O+G))
B(O+G +SOT +
5 Point
TC(O+SOT(O))) T(O+G+SOT))
B(O+G+TC(O+G+SOT(O+G)))
6 Point
T(O+G+SOT))
B(O+G+SOT+TC(O+G+SOT(O
7 Point
+G))) T(O+G+SOT))
2 Point
3 Point
T(O+G+SOT)
Depending on the calibration type, the corresponding number of calibration points is displayed in the Calibration Points Position graph to
illustrate the coverage of the measurement range. The table below the drop-down menu automatically updates the number of entries,
based on the selected calibration type. It contains up to 7 rows and 4 columns for each combination of sensor and temperature conditions.
S[%]
External sensor measurement reference point. The point should be entered as a percent of the full measurement
range.
S[counts]
Raw external sensor measurement result in counts.
T[°C]
Temperature measurement reference point. Enter this point in Celsius degrees.
T[counts]
Raw temperature measurement result in counts.
The columns S[%] and T[ºC] have predefined values entered that could be changed if necessary. The columns S[counts] and T[counts]
are usually updated with the result from the measurement when the button Get Measurement Value for Calibration is pressed, see Figure
40. Alternatively the raw measurement input can be done manually by entering the number into the cell after a double click on it.
2.7.3.2 Coefficients
The bottom right section in the Calibration tab is the Coefficient table, where the coefficients are displayed after calculation. If one of the
coefficients exceeds the range limits, its value appears as a red number. In this case, the status window displays
out of
range!"

2.7.4 Diagnostic / Cyclic Configuration / Command Section

In Figure 34 the overview of the tab is provided. There are 5 sub-tab areas that are discussed in sections 2.7.4.1, 2.7.4.2, 2.7.4.3, 2.7.4.4,
and 2.7.4.5.
© 2020 Renesas Electronics Corporation
GUI
B(O+G)
T(O+G)
Calculated coefficients
32
ZSSC324x Kit User Manual
Required set points
External
Sensor
2
3
2
3
3
3
0
0
"Calculated coefficients
Temperature
0
0
2
3
2
3
2
3
April 15, 2020