8-4 Troubleshooting
On-screen error message
0B70
The error occurred during temperature sensor
reading
0B71
System Temperature out of the range
0B74
The error occurred during voltage sensor reading
0B75
System Voltage out of the range
0B78
The error occurred during fan sensor reading
0B7C The error occurred during redundant power module
confirmation
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A BMC SEL area full.
0B8B BMC progress check timeout
0B8C BMC command access failed.
0B8D Could not redirect the console
- BMC Busy -
0B8E Could not redirect the console
- BMC Error -
0B8F Could not redirect the console
- BMC Parameter Error -
0B90
BMC Platform information Area Corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
Action
Contact your service representative.
The fan may be faulty or clogged with
dust.
Contact your service representative for
maintenance.
Contact your service representative.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
Run SETUP and select [Server] -
[Event Log Configuration] - [Clear All
Error Logs] to clear error logs.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
FRU command and EMP feature are
unavailable. This is not a fatal error;
however, power-off and reboot the
CPU blade. If the error persists, contact
your service representative.
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
Access to SMC via IPMB is
unavailable. This is not a fatal error;
however, power-off and reboot the
CPU blade. If the error persists, contact
your service representative.
FRU command and EMP feature are
unavailable. This is not a fatal error;
however, power-off and reboot the
CPU blade. If the error persists, contact
your service representative.

Advertisement