ADF Web HD67767-IP-A1 User Manual

ADF Web HD67767-IP-A1 User Manual

Iec61850 client / bacnet slave - converter
Hide thumbs Also See for HD67767-IP-A1:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
IEC61850 Client / BACnet Slave -
Converter
(Order Code: HD67767-IP-A1, HD67767-MSTP-A1)
for Website information:
http://www.adfweb.com/?Product=HD67767
for Price information:
http://www.adfweb.com/?Price=HD67767-IP-A1
http://www.adfweb.com/?Price=HD67767-MSTP-A1
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual IEC61850 Client / BACnet Slave
Document code: MN67767_ENG
Revision 1.000
For others IEC61850 Client devices, see also the following links:
IEC61850 Client from/to ...
www.adfweb.com?Product=HD67D34
www.adfweb.com?Product=HD67E14
www.adfweb.com?Product=HD67765
www.adfweb.com?Product=HD67766
www.adfweb.com?Product=HD67768
www.adfweb.com?Product=HD67769
www.adfweb.com?Product=HD67770
www.adfweb.com?Product=HD67771
www.adfweb.com?Product=HD67772
www.adfweb.com?Product=HD67773
www.adfweb.com?Product=HD67774
www.adfweb.com?Product=HD67775
www.adfweb.com?Product=HD67776
www.adfweb.com?Product=HD67777
www.adfweb.com?Product=HD67778
www.adfweb.com?Product=HD67779
www.adfweb.com?Product=HD67780
www.adfweb.com?Product=HD67781
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Page 1 of 32
(LoRaWAN)
(EtherCAT)
(Modbus Slave)
(Modbus TCP Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(EtherNet/IP Slave)
(J1939)
(KNX)
(MQTT)
(NMEA0183)
(NMEA2000)
(PROFIBUS)
(PROFINET)
(SNMP Agent)
(Serial)
(Ethernet)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading

Summary of Contents for ADF Web HD67767-IP-A1

  • Page 1 Page 1 of 32 Industrial Electronic Devices User Manual Revision 1.000 English IEC61850 Client / BACnet Slave - Converter (Order Code: HD67767-IP-A1, HD67767-MSTP-A1) For others IEC61850 Client devices, see also the following links: for Website information: http://www.adfweb.com/?Product=HD67767 IEC61850 Client from/to … www.adfweb.com?Product=HD67D34 (LoRaWAN) www.adfweb.com?Product=HD67E14...
  • Page 2: Table Of Contents

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 2 of 32 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 3 of 32 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 4 of 32 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 5 of 32 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67767-IP-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 6 of 32 Industrial Electronic Devices Figure 1b: Connection scheme for HD67767-MSTP-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7: Characteristics

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 7 of 32 Industrial Electronic Devices CHARACTERISTICS: The HD67767-A1 is a IEC61850 Client / BACnet Slave converter. It allows the following characteristics: Two-directional information between BACnet and IEC61850; Mountable on 35mm Rail DIN;...
  • Page 8: Power Supply

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 8 of 32 Industrial Electronic Devices POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 9: Function Modes

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 9 of 32 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 10: Leds

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 10 of 32 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 11: Ethernet

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 11 of 32 Industrial Electronic Devices ETHERNET: The Ethernet connection must be made using Connector3 or Connector4 of HD67767-xxxx-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 12: Rs485

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 12 of 32 Industrial Electronic Devices RS485 (for BACnet MS/TP): To terminate the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet).
  • Page 13: Use Of Compositor Sw67767

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 13 of 32 Industrial Electronic Devices USE OF COMPOSITOR SW67767: To configure the Converter, use the available software that runs with Windows called SW67767. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Project / Open Project

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 14 of 32 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “IEC61850 Client / BACnet Slave - Converter”...
  • Page 15: Software Options

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 15 of 32 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor. In the section “Language”...
  • Page 16 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 16 of 32 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 17: Set Communication

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 17 of 32 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, IEC61850 and BACnet. By Pressing the “Set Communication” button from the main window for SW67767 (Fig.
  • Page 18 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 18 of 32 Industrial Electronic Devices In the field “Port” the port used for BACnet communication is defined. The default port used for BACnet communication is 47808, but is possible to insert any value;...
  • Page 19: Iec61850 Access

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 19 of 32 Industrial Electronic Devices IEC61850 ACCESS: By Pressing the “IEC61850 Access” button from the main window for SW67767 (Fig. 2) the window “IEC61850 Client Set Access” appears (Fig.
  • Page 20 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 20 of 32 Industrial Electronic Devices By clicking on “ADD IEC Device”, it is possible to add a new IEC61850 Server. A SCL file has to be selected (the allowed extensions are .scd, .ssd, .sed, .icd, .iid or .cid).
  • Page 21 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 21 of 32 Industrial Electronic Devices Figure 6: “Variables” section The meanings of the fields are: In the field “Index” the index of the server to which the IEC61850 variable belongs is defined; In the field “bType”...
  • Page 22 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 22 of 32 Industrial Electronic Devices If the field “On Timer” is checked, the IEC61850 variable is sent/read cyclically; In the field “Time (ms)” the delay in ms between two readings/writings of the variable is defined (if “On Timer” is checked); In the field “Position”...
  • Page 23 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 23 of 32 Industrial Electronic Devices If they are available in the functional structure, it is also possible to add Datasets (DS) to “DataSet” section (Fig. 7). Figure 7: “DataSet”...
  • Page 24 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 24 of 32 Industrial Electronic Devices In the lower part, it is possible to see the variables which belong to the selected Dataset. The meanings of the fields are: In the field “bType”...
  • Page 25: Set Bacnet Access

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 25 of 32 Industrial Electronic Devices SET BACNET ACCESS: By Pressing the “Set BACnet Access” button from the main window for SW67767 (Fig. 2) the window “BACnet Set Access” appears (Fig. 8). The window is divided in two parts, the “BACnet in Read”...
  • Page 26 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 26 of 32 Industrial Electronic Devices It is possible to insert directly the Unit (using its unique number) by compiling the “Selected BACnet Engineering Unit” field; or by selecting with the fields “Select the Type”...
  • Page 27: Update Device

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 27 of 32 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 28 User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 28 of 32 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67767 device. Warning: If Fig.
  • Page 29: Mechanical Dimensions

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 29 of 32 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 12: Mechanical dimensions scheme for HD67767-xxx-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 30: Ordering Informations

    BACnet Type IP: BACnet/IP MSTP: BACnet MS/TP Device Family HD67767: IEC61850 Client / BACnet Slave - Converter Order Code: HD67767-IP-A1 IEC61850 Client / BACnet/IP Slave – Converter Order Code: HD67767-MSTP-A1 IEC61850 Client / BACnet MS/TP Slave – Converter ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 31: Disclaimer

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 31 of 32 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 32: Warranties And Technical Support

    User Manual IEC61850 Client / BACnet Slave Document code: MN67767_ENG Revision 1.000 Page 32 of 32 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents