ADF Web HD67738-IP-A1 User Manual

Iec 61850 server / bacnet slave - converter
Hide thumbs Also See for HD67738-IP-A1:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
IEC 61850 Server / BACnet Slave - Converter
(Order Code: HD67738-IP-A1 , HD67738-MSTP-A1)
For Website information:
www.adfweb.com?Product=HD67738
For Price information:
www.adfweb.com?Price=HD67738-IP-A1
www.adfweb.com?Price=HD67738-MSTP-A1
Benefits and Main Features:
Very easy to configure
Triple Electrical isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual IEC 61850 Server / BACnet Slave
Document code: MN67738_ENG
For other IEC 61850 products see also the following link:
Converter IEC 61850 Server to
www.adfweb.com?Product=HD67B82
www.adfweb.com?Product=HD67620
www.adfweb.com?Product=HD67733
www.adfweb.com?Product=HD67734
www.adfweb.com?Product=HD67735
www.adfweb.com?Product=HD67736
www.adfweb.com?Product=HD67737
www.adfweb.com?Product=HD67739
www.adfweb.com?Product=HD67740
www.adfweb.com?Product=HD67741
www.adfweb.com?Product=HD67743
www.adfweb.com?Product=HD67744
www.adfweb.com?Product=HD67745
www.adfweb.com?Product=HD67746
www.adfweb.com?Product=HD67747
www.adfweb.com?Product=HD67748
www.adfweb.com?Product=HD67749
www.adfweb.com?Product=HD67750
www.adfweb.com?Product=HD67751
www.adfweb.com?Product=HD67752
www.adfweb.com?Product=HD67753
www.adfweb.com?Product=HD67754
www.adfweb.com?Product=HD67755
www.adfweb.com?Product=HD67756
www.adfweb.com?Product=HD67765
Do you have your customer protocol? Then go to:
www.adfweb.com?Product=HD67003
Do you need to choose a device? Do you want help?
www.adfweb.com?Cmd=helpme
Revision 1.000
Page 1 of 30
(PROFINET Master)
(S7comm)
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(BACnet Master)
(CAN)
(CANopen)
(DeviceNet Master)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(KNX)
(MQTT)
(NMEA0183)
(NMEA2000)
(PROFIBUS Master)
(PROFIBUS Slave)
(PROFINET Slave)
(SNMP Manager)
(SNMP Agent)
(Serial)
(Ethernet)
(EnOcean)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67738-IP-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67738-IP-A1

  • Page 1 Industrial Electronic Devices User Manual Revision 1.000 English IEC 61850 Server / BACnet Slave - Converter (Order Code: HD67738-IP-A1 , HD67738-MSTP-A1) For other IEC 61850 products see also the following link: Converter IEC 61850 Server to For Website information: www.adfweb.com?Product=HD67B82 (PROFINET Master) www.adfweb.com?Product=HD67738...
  • Page 2: Table Of Contents

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 2 of 30 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that INDEX you need to check that the following document is: UPDATED DOCUMENTATION Updated REVISION LIST...
  • Page 3: Security Alert

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 4 of 30 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 5 of 30 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67738-IP-A1 ADFweb.com S.r.l.
  • Page 6 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 6 of 30 Industrial Electronic Devices Figure 1b: Connection scheme for HD67738-MSTP-A1 ADFweb.com S.r.l.
  • Page 7: Characteristics

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 7 of 30 Industrial Electronic Devices CHARACTERISTICS: The HD67738-xxx-A1 are IEC 61850 / BACnet - Converters. It allows for the following characteristics: Triple isolation between RS232/RS485/RS422 - Power Supply, RS232/RS485/RS422 - Ethernet, Ethernet - Power Supply; Two-directional information between IEC 61850 bus and BACnet bus;...
  • Page 8: Power Supply

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 8 of 30 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 9: Function Modes

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 9 of 30 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 10: Leds

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 10 of 30 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 11: Ethernet

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 11 of 30 Industrial Electronic Devices ETHERNET: IEC 61850 connection, BACnet/IP connection and the updating of the converters must be made using Connector3 and/or Connector4 of the HD67738-XXX-A1 with at least a Category 5E cable.
  • Page 12: Rs485 (For Bacnet Ms/Tp)

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 12 of 30 Industrial Electronic Devices RS485 (for BACnet MS/TP): For terminating the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet).
  • Page 13: Use Of Compositor Sw67738

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 13 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67738: To configure the Converter, use the available software that runs with Windows called SW67738. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Configuration / Open Configuration

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 14 of 30 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “IEC 61850 Server / BACnet Slave - Converter”...
  • Page 15: Software Options

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 15 of 30 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 16 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 16 of 30 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 17: Set Communication

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 17 of 30 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67738 (Fig. 2) the window “Set Communication” appears (Fig. 3). The window is divided in different sections in order to define the different parameters of the converter: IEC 61850 Server...
  • Page 18 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 18 of 30 Industrial Electronic Devices IEC 61850 S ERVER This section is used to define the main parameters of IEC 61850 line. The means of the fields are: In the field “Port”...
  • Page 19 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 19 of 30 Industrial Electronic Devices LAVE This section is used to define the main parameters of BACnet line. It is possible to select the type of BACnet to use from: BACnet/IP (it uses Ethernet);...
  • Page 20 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 20 of 30 Industrial Electronic Devices In the field “MAC Address” the MAC of BACnet MS/TP side of the converter is defined; The field “Max Masters” specifies the highest allowable address for master nodes.
  • Page 21: Iec 61850 Access

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 21 of 30 Industrial Electronic Devices IEC 61850 ACCESS: By Pressing the “IEC 61850 Access” button from the main window for SW67738 (Fig. 2) the window “Set Variables Access for IEC 61850” appears (Fig.
  • Page 22: Set Bacnet Access

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 22 of 30 Industrial Electronic Devices SET BACNET ACCESS: By Pressing the “Set BACnet Access” button from the main window for SW67738 (Fig. 2) the window “BACnet Set Access” appears (Fig. 5). The window is divided in two parts, the “BACnet in Read”...
  • Page 23 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 23 of 30 Industrial Electronic Devices It is possible to insert directly the Unit (using its unique number) by compiling the “Selected BACnet Engineering Unit” field; or by selecting with the fields “Select the Type”...
  • Page 24: Tls Known Certificate

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 24 of 30 Industrial Electronic Devices TLS KNOWN CERTIFICATE: Figure 7: “TLS Known Certificate” window By pressing the “TLS Known Certificate” button from the Main Window of SW67738 (Fig. 2) the “Definition the list of Known Certificates” window appears (Fig.
  • Page 25: Update Device

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 25 of 30 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 26 User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 26 of 30 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67738 device. Warning: If Fig.
  • Page 27: Mechanical Dimensions

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 27 of 30 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 10: Mechanical dimensions scheme for HD67738-XXX-A1 ADFweb.com S.r.l.
  • Page 28: Ordering Informations

    IP: BACnet/IP MSTP: BACnet MS/TP Device Family HD67738: IEC 61850 Server / BACnet Slave - Converter Order Code: HD67738-IP-A1 IEC 61850 Server / BACnet/IP Slave - Converter Order Code: HD67738-MSTP-A1 IEC 61850 Server / BACnet MS/TP Slave - Converter ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 29: Disclaimer

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 29 of 30 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 30: Warranties And Technical Support

    User Manual IEC 61850 Server / BACnet Slave Document code: MN67738_ENG Revision 1.000 Page 30 of 30 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents