ADF Web HD67718-IP-A1 User Manual

ADF Web HD67718-IP-A1 User Manual

Bacnet master / canopen - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
BACnet Master / CANopen - Converter
(Order Code: HD67718-IP-A1, HD67718-MSTP-A1, HD67718-MSTP-B2 )
For Website information:
www.adfweb.com?Product=HD67718
For Price information:
www.adfweb.com?Price=HD67718-IP-A1
www.adfweb.com?Price=HD67718-MSTP-A1
www.adfweb.com?Price=HD67718-MSTP-B2
Benefits and Main Features:
Very easy to configure
Triple Electrical isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual BACnet Master / CANopen
Document code: MN67718_ENG
For other BACnet Master Slave products see also the following link:
Converter BACnet Master to
www.adfweb.com?Product=HD67704
www.adfweb.com?Product=HD67712
www.adfweb.com?Product=HD67714
www.adfweb.com?Product=HD67716
www.adfweb.com?Product=HD67717
www.adfweb.com?Product=HD67719
www.adfweb.com?Product=HD67721
www.adfweb.com?Product=HD67722
www.adfweb.com?Product=HD67723
www.adfweb.com?Product=HD67725
www.adfweb.com?Product=HD67726
www.adfweb.com?Product=HD67737
www.adfweb.com?Product=HD67801
www.adfweb.com?Product=HD67832
www.adfweb.com?Product=HD67937
www.adfweb.com?Product=HD67965
www.adfweb.com?Product=HD67B31
www.adfweb.com?Product=HD67D16
www.adfweb.com?Product=HD67E05
Revision 1.000
Page 1 of 38
(DMX)
(Modbus Slave)
(Modbus TCP Slave)
(PROFIBUS Slave)
(CAN)
(PROFINET Slave)
(DeviceNet Slave)
(EtherNet/IP Slave)
(NMEA 2000)
(J1939)
(SNMP Agent)
(IEC 61850 Server)
(KNX)
(DALI)
(MQTT)
(IO-Link Slave)
(OPC UA Server)
(LoRaWAN)
(EtherCAT)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67718-IP-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67718-IP-A1

  • Page 1 Revision 1.000 Page 1 of 38 Industrial Electronic Devices User Manual Revision 1.000 English BACnet Master / CANopen - Converter (Order Code: HD67718-IP-A1, HD67718-MSTP-A1, HD67718-MSTP-B2 ) For Website information: www.adfweb.com?Product=HD67718 For Price information: www.adfweb.com?Price=HD67718-IP-A1 www.adfweb.com?Price=HD67718-MSTP-A1 www.adfweb.com?Price=HD67718-MSTP-B2 For other BACnet Master Slave products see also the following link:...
  • Page 2: Table Of Contents

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 2 of 38 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that INDEX you need to check that the following document is: UPDATED DOCUMENTATION Updated REVISION LIST...
  • Page 3: Security Alert

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 3 of 38 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 4 of 38 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 5 of 38 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67718-IP-A1 ADFweb.com S.r.l.
  • Page 6 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 6 of 38 Industrial Electronic Devices Figure 1b: Connection scheme for HD67718-MSTP-A1 ADFweb.com S.r.l.
  • Page 7 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 7 of 38 Industrial Electronic Devices Figure 1c: Connection scheme for HD67718-MSTP-B2 ADFweb.com S.r.l.
  • Page 8: Characteristics

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 8 of 38 Industrial Electronic Devices CHARACTERISTICS: The HD67718 are BACnet Master / CANopen - Converters. It allows for the following characteristics: Isolation between BACnet – CANopen – Power Supply; Two-directional information between BACnet bus and CANopen bus;...
  • Page 9: Power Supply

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 9 of 38 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax...
  • Page 10: Function Modes

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 10 of 38 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 11: Leds

    Revision 1.000 Page 11 of 38 Industrial Electronic Devices LEDS: HD67718-IP-A1 The device has got six LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode...
  • Page 12 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 12 of 38 Industrial Electronic Devices HD67718-MSTP-A1/B2 The device has four LEDs (five for the B2 version) that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 13: Ethernet

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 13 of 38 Industrial Electronic Devices ETHERNET: The Ethernet port is used for programming the device and for BACnet/IP communication. The Ethernet connection must be made using Connector2 of HD67718-xxx-xx with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 14: Can

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 14 of 38 Industrial Electronic Devices CAN: For terminating the CAN line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch B’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 15: Rs485

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 15 of 38 Industrial Electronic Devices RS485 (for BACnet MS/TP): For terminating the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet).
  • Page 16: Use Of Compositor Sw67718

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 16 of 38 Industrial Electronic Devices USE OF COMPOSITOR SW67718: To configure the Converter, use the available software that runs with Windows called SW67718. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 17: New Configuration / Open Configuration

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 17 of 38 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “BACnet Master / CANopen - Converter”...
  • Page 18: Software Options

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 18 of 38 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 19 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 19 of 38 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 20: Set Communication

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 20 of 38 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, CANopen and BACnet Slave. By Pressing the “Set Communication” button from the main window for SW67718 (Fig. 2) the window “Set Communication”...
  • Page 21 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 21 of 38 Industrial Electronic Devices The field “Max Info Frames” specifies the maximum number of information frames the node may send before it must pass the token; In the field “Device Istance”...
  • Page 22: Set Bacnet Access

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 22 of 38 Industrial Electronic Devices SET BACNET ACCESS: By Pressing the “Set BACnet Access ” button from the main window of SW67718 (Fig. 2), the window “Set BACnet Access” appears (Fig. 4).
  • Page 23 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 23 of 38 Industrial Electronic Devices In the field “Poll Time” the frequency of the request is defined (in ms); In the field “Max Error” the number of consecutive errors that the Master waits before resetting the data for the specific requests is defined;...
  • Page 24 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 24 of 38 Industrial Electronic Devices Figure 4b: “Set BACnet Access  BACnet Write” window The means of the fields in the window “BACnet in Write” are the following: If the field “Enable”...
  • Page 25 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 25 of 38 Industrial Electronic Devices In the field “Max Error” the number of consecutive errors that the Master waits before stopping the specific requests is defined; In the field “Position” the starting byte of the internal memory array from which taking the data to write is defined; The field “Start Bit”...
  • Page 26: Set Sdo Server

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 26 of 38 Industrial Electronic Devices SET SDO SERVER: By pressing the “Set SDO Server” button from the main window for SW67718 (Fig. 2) the window “Set SDO Server Access” appears (Fig.
  • Page 27: Set Sdo Client

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 27 of 38 Industrial Electronic Devices SET SDO CLIENT: By pressing the “Set SDO Client” button from the main window for SW67718 (Fig. 2) the window “Set SDO Client Access” appears (Fig. 6a and 6b).
  • Page 28 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 28 of 38 Industrial Electronic Devices The data of the columns in the “SDO Write” have the following meanings: In the field "ID Device" insert the ID of the device to write;...
  • Page 29: Pdo Access

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 29 of 38 Industrial Electronic Devices SET PDO ACCESS: By pressing the “Set PDO Access” button from the main window for SW67718 (Fig. 2) the window “Set PDO Access” appears (Fig. 7a and 7b).
  • Page 30: Eds File

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 30 of 38 Industrial Electronic Devices The data of the columns in the “Transmit PDO” have the following meanings: In the Field "Cob-ID" the address for the PDO is defined;...
  • Page 31: Update Device

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 31 of 38 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 32 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 32 of 38 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67718 device. Warning: If Fig.
  • Page 33: Mechanical Dimensions

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 33 of 38 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 10a: Mechanical dimensions scheme for HD67718-IP-A1 ADFweb.com S.r.l.
  • Page 34 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 34 of 38 Industrial Electronic Devices Figure 10b: Mechanical dimensions scheme for HD67718-MSTP-A1 ADFweb.com S.r.l.
  • Page 35 User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 35 of 38 Industrial Electronic Devices Figure 10c: Mechanical dimensions scheme for HD67718-MSTP-B2 ADFweb.com S.r.l.
  • Page 36: Ordering Informations

    BACnet port IP: BACnet/IP MSTP: BACnet MS/TP Device Family HD67718: BACnet Master / CANopen - Converter Order Code: HD67718-IP-A1 BACnet/IP Master / CANopen – Converter Order Code: HD67718-MSTP-A1 BACnet MS/TP Master / CANopen – Converter Order Code: HD67718-MSTP-B2 BACnet MS/TP Master / CANopen – Converter...
  • Page 37: Disclaimer

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 37 of 38 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 38: Warranties And Technical Support

    User Manual BACnet Master / CANopen Document code: MN67718_ENG Revision 1.000 Page 38 of 38 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67718-mstp-a1Hd67718-mstp-b2