TROUBLESHOOTING

LCD Display References

The control board is equipped with a LCD Display that provides operator information,
current conditions, settings, diagnostics and error messages. Use the table below to
identify the corresponding "TS Ref#" and refer to page 39 for further troubleshooting.
Meaning
LCD MSG
MODEL
Indicates the Model of the unit. G-5 or X-9 Solar.
G5S/X9S
System Status Messages
GATE IS
Gate is stopped between limits.
IDLE
GATE IS
Gate is opening.
OPENING
GATE IS
Gate is closing.
CLOSING
GATE IS
Gate is at the limit open position.
OPENED
GATE IS
Gate is at the limit close position.
CLOSED
STOP BY
Master or Single motor has stopped due to an obstruction of the gate
system. Also refer to the "ODS" LED. (pg 27, 34, 35 @ 18)
OBSTRUCT
STOP BY
Master or Single motor has stopped due to an overload of the gate system.
Also refer to the "ODS" LED. (pg 27, 34, 35 @ 18)
OVERLOAD
OVERLAP
Gate is waiting for the overlap time.
TIMING
HOLDING
Gate is at the limit open position and timing to close - The display shows
the actual time left before closing.
__ SEC
STOP BY
Slave motor has stopped due to an obstruction sensor event. Also refer to
the "DIAGNOSE" LED on the Slave Module. (pg 27, 34, 35 @ S1)
ODS
S
UL LEARN
Indicates the number of connected Monitored Entrapment Protection
Sensors that are being monitored. NO LEARN = no sensors learned. (pg 11)
UL_ RO_
3 6
www.PerformanceGateOpeners.com | (800) 878-7829 | Sales@PerformanceGateOpeners.com
1. Error Messages will be displayed first.
2. The "Diagnose" LED will flash consecutively
indicating how many Error Messages are
available.
3. Press the Diagnose button to manually
scroll through all of the Messages.
Page 39
TS Ref #s
11, 12,
13
11, 12
11, 12,
13