Important
The Quinta Ace must be installed by a qualified installer in
accordance with local and national regulations.
Warning
The installer must be registered with Gas Safe and have the
correct ACS qualifications.
Important
Practical guidelines - see the latest version.
When choosing the best installation location, consider:
The regulations.
The required installation space.
The required space around the boiler for good access and to facilitate
maintenance.
The required space under the boiler for the installation and removal of
the siphon.
The permitted position of the flue gas outlet and/or air supply opening.
The evenness of the surface.
A ≥ 1000 mm
B 500 mm
C 500 mm
C
D ≥ 400 mm
E 750 mm
F 350 mm (siphon)
G ≥ 250 mm
D
If the boiler is installed in a closed cupboard, the minimum distance
between the boiler and the walls of the cupboard must be taken into
account.
1 ≥ 1000 mm (front)
E
2 ≥ 15 mm (left-hand side)
3 ≥ 15 mm (right-hand side)
Also allow for openings to prevent the following hazards:
Accumulation of gas
F
Heating of the casing
Minimum cross section of the openings: S1 + S2 = 150 cm
G
3
AD-3001371-01