3 Use of the control panel
Tab.1
Components in the example
Item
Description
CU
Control Unit: Control unit
CB
Connection Board: Connection PCB
SCB
Smart Control Board: Expansion PCB
GTW
Gateway: Conversion PCB
MK
Control panel: Control panel and display
RU
Room Unit: Room unit (for example, a thermo
stat)
L-Bus
Local Bus: Connection between devices
S-Bus
System Bus: Connection between appliances
R-Bus
Room unit Bus: Connection to a room unit
A
Device
B
Appliance
C
System
Tab.2
Specific devices delivered with the Quinta Ace boiler
Name visible
Software ver
in display
sion
CU-GH08
1.12
MK3
1.85
SCB-01
1.3
3
Use of the control panel
3.1
Control panel components
Fig.3
Control panel components
3
4
5
6
3.2
Description of the home screen
6
Description
Control unit CU-GH08
Control panel HMI T-control
Expansion PCB SCB-01
1 Rotary knob to select a tile, menu or setting
2 Confirm button
3 Back button
2
4 Menu button
1
5 Display
6 Status LED
AD-3000932-02
This screen is shown automatically after start-up of the appliance. The
control panel automatically enters standby mode (black screen) if the
buttons are not used for 5 minutes. Press one of the buttons on the control
panel to activate the screen again.
Function
The control unit handles all basic functionality of the appli
ance.
The connection PCB provides easy access to all connectors
of the control unit.
An expansion PCB provides extra functionality, like an internal
calorifier or multiple zones.
A gateway can be fitted to an appliance or system, to provide
one of the following:
Extra (wireless) connectivity
Service connections
Communication with other platforms
The control panel is the user interface to the appliance.
A room unit measures the temperature in a reference room.
The local bus provides communication between devices.
The system bus provides communication between appliances.
The room unit bus provides communication to a room unit.
A device is a PCB, control panel or a room unit.
An appliance is a set of devices connected via the same L-
Bus
A system is a set of appliances connected via the same S-Bus
Function
The CU-GH08 control unit handles all basic functionality of the
Quinta Ace boiler.
The HMI T-control is the user interface to the Quinta Ace boil
er.
The SCB-01 provides a 0-10 V connection for a PWM system
pump and two potential-free contacts for status notification.
to confirm the selection
:
Short button press: Return to the previous level or previous
menu
Long button press: Return to home screen
to go to the main menu
7703943 - v.06 - 13122021