6.4.2
SCB-01 expansion PCB counters
Tab.31
Navigation for basic installer level
Level
Menu path
Basic installer
(1) See the column "Submenu" in the following table for the correct navigation. The counters are grouped in specific functionalities.
Tab.32
Counters at basic installer level
Code
Display text
AC001
Hours on mains
6.4.3
CU-GH08 control unit signals
Tab.33
Navigation for basic installer level
Level
Menu path
Basic installer
(1) See the column "Submenu" in the following table for the correct navigation. The signals are grouped in specific functionalities.
Tab.34
Signals at basic installer level
Code
Display text
AM001
DHW active
AM010
Pump speed
AM011
Service required?
AM012
Status Appliance
AM014
Sub status Appli
ance
AM015
Pump running?
AM016
System Flow Temp Flow temperature of appliance.
AM018
T return
AM019
Water pressure
AM022
On / Off heat de
mand
AM027
Outside tempera
ture
7703943 - v.06 - 13122021
> Installation Setup > SCB-01 > Submenu
Description
Number of hours that the appliance has
been on mains power
> Installation Setup > CU-GH08 > Submenu
Description
Is the appliance currently in domestic hot
water production mode?
The current pump speed
Is service currently required?
Current main status of the appliance.
Current sub status of the appliance.
Is the pump running?
Return temperature of appliance. The
temperature of the water entering the ap
pliance.
Water pressure of the primary circuit.
On / Off heat demand
Instantaneous outside temperature
> Parameters, counters, signals > Counters > General
(1)
Range
0 - 4294967295Hours
> Parameters, counters, signals > Signals > General
(1)
Range
0 = Off
1 = On
0 - 100%
0 = No
1 = Yes
See
Status and sub-status,
page 35
See
Status and sub-status,
page 35
0 = Inactive
1 = Active
-25 - 150°C
-25 - 150°C
0 - 4bar
0 = Off
1 = On
-60 - 60°C
6 Settings
Submenu
System Func
tionality
Submenu
Tank DHW
Gas fired ap
pliance
Gas fired ap
pliance
Gas fired ap
pliance
System Func
tionality
System Func
tionality
Gas fired ap
pliance
Tank DHW
Producer Ge
neric
Gas fired ap
pliance
Tank DHW
Gas fired ap
pliance
Gas fired ap
pliance
Gas fired ap
pliance
Outdoor tem
perature
Gas fired ap
pliance
31