Technical Information - ensto ECO16TOUCH Installation And Operating Instructions Manual

Hide thumbs Also See for ECO16TOUCH:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
11.

Technical information

Supply voltage
Rated current
Power
Switch
Thermostat adjustment range
Clock function
Power in standby
Battery backup
Ambient temperature
Ball pressure temperature (TB)
ELV limits realized
Pollution degree rating
Rated impulse voltage
Regulation principle
Software class
Display
Terminal wire size
Floor sensor
Floor sensor resistance values
Ingress Protection
16 / 56
230 V AC ±10%, 50/60 Hz
16 A resistive load or 1 A inductive load
3600 W
2-pole, 16 A
+5 ... +40 °C
4- or 6-event program
0,5 W
5 years
0 ... +40 °C
125 °C
SELV 24 V
2
4 kV
PWM / PI
A
220 x 176 pixel TFT - Color resistive touch display
1.5 - 2.5 mm²
NTC, 47 kΩ/ 25°C, cable 4 m (extendable to 10m
MMJ2x1,5mm²)
Table 1, on page 55 (sensor not connected)
IP21
RAK110 / 12.8.2021