Modifi Cation From The Right-Hand To Left-Hand Outlet Side; Opening Front Panel - iDM AERO ILM 2-7 Installation Instructions Manual

Modulation air-water-heat pumps for indoor installation
Table of Contents

Advertisement

5. General description
Installation
5.14. Modifi cation from the right-hand to left-hand outlet side
The AERO ILM heat-pumps are supplied according
to the manufacturer's specifi cations for a right-hand
side outlet. The electric and hydraulic connections
are therefore on the left-hand side.
If necessary, the connection side can be altered.
In the case of an outlet on the left-hand side, the up-
per, left-handed panel (panel opposite the outlet) has
to be mounted on the right-hand side. In this case
remove the 4 fi xing screws. The trapeze-shaped in-
sulation has to be affi xed as shown in the illustration
below.
If it is necessary to change the hydraulic pipework
itself, no changes to the heat pump are necessary.
The protective sleeves for the hydraulics and cables
are provided by the manufacturer on both sides.
The fl exible connection hoses. the condensation run-
off hose, the safety valve hose and the cabling have
to be installed as shown in the diagram below.
44
Installation instructions AERO ILM
In the next step the connecting cables next to the
50 l heating buff er are laid to the electric switch box
and fastened with cable binders. All cover panels
are then remounted.
The screws on the panel have to be
carefully tightened manually.

5.15. Opening front panel

The front panel consists of the left and the right part.
At the bottom of the left part there is a handle. At this,
the left side is pulled forward, and then unhooked on
the top.