5.12.3. Assembly instructions - fl exible air hose - air outlet sideways
Air inlet side
Procedure as in corner installation
Outlet panel:
The outlet panel is mounted to the desired side using
the 4 screws included in the delivery contents.
Example of outlet side on the right
A trapeze-shaped insulation with adhesive tape on
both sides is included with the outlet panel. This has
to be affi xed to the panel on the evaporator side.
Wall fl ange:
The wall fl ange has to be mounted to the air outlet
opening using suitable assembly material. Four bore
holes in the corners of the fl ange are provided for that
purpose!
Flexible hose:
The hose can be cut to length as desired! In connect-
ing the hose with the two fl anges the hose insulation
is telescoped at the two ends.
(C) IDM Energiesysteme GmbH
The hose is mounted to the fl ange using a hose
clamp. This enables the insulation to be extended
over the fl ange again!
The air hose is fl exible and enables an outlet in all
directions. The minimum bending radius is 600 mm!!
Installation instructions AERO ILM
The air hose should be straight as far as
possible and should not make any un-
necessary changes in direction . The air
hose should be suspended every 0.5 m
with an assembly tape (perforated tape)!
The heat pump must only be moved us-
ing the mounted panels!
Installation
39