2. General description
Technical data
Heatpump type
Maximum heatpump flow temperature ⁵
Nominal flow rate heating water (A7°C/W35°C, ΔT=5 K)
Flow rate heating water (A7°C/W55°C, ΔT=8 K)
Integrated loading pump
Free residual pressure loading pump at nominal flow rate
Pressure loss heating side
Flow- and return connections heating side
Flow domestic hot water heater or HGL-flow
Condensate run-off connection
Maximum operating pressure heating side
Residual pressure at maximum speed ¹
Nominal air flow rate (A7°C/W35°C
and nominal Compressor speed)
diameter flexible air outlet hose (accessory)
Refrigerant
Quantity of refrigerant
2
GWP
3
Minimum size of installation room
Quantity of compressor oil (FV50S)
Quantity of compressors
1
If the fan speed will be raised, the sound power level raises too
² AERO ILM heat pumps work with the by the Kyoto protocol detected safety refrigerant R410A, with a global warming potential of 2088.
3
According to the 5th IPCC report
If the installation room falls below the required minimum size, it must be constructed as a machine room in accordance with EN 378.
4
⁵ The 62°C refers to the max heat pump flow temperature. The resulting lower hot water temperature must be checked in relation to compliance with the drinking water
regulations.
Electrical data
Electrical power supply compressor
Electrical power supply heating element
Electrical power supply controller
Maximum operating (starting) current of compressor
Maximum power consumption electric heating element
Fuse of control supply
Fuse of electrical heating element
Fuse of main power supply compressor
Maximum operating current of fan
Maximum power consumption fan
Protection class
10
4
Installation instructions AERO ILM
unit
AERO ILM 2-7
°C
62
m³/h
0.8
m³/h
0.42
Yonos Para 7.0
kPa
49
kPa
15
R
1" AG
R
1" AG
R
35 mm
bar
3
Pa
150
m³/h
1,250
mm
560
R410A
kg
3.2
7.3
lt.
0.35
qty
1
unit
AERO ILM 2-7
V/Hz
1~ 230/50
3~ 400/50 or
V/Hz
1~ 230/50
V/Hz
1~ 230/50
A
15.8
A
8.7
A
B/Z 13
if 3~ 400/50 B/Z 13
A
if 1~ 230/50 B/Z 32
A
C/K 16
A
0.24
W
56
-
IP 20
AERO ILM 4-13
60
1.42
0.77
Stratos Para 25/1-9
77
11
1" AG
1" AG bzw. 5/4" AG
35 mm
3
110
2,200
560
R410A
6.2
1924
14.1
1.9
1
AERO ILM 4-13
3~ 400/50
3~ 400/50
1~ 230/50
19.0
8.7
B/Z 13
B/Z 13
C/K 20
0.5
115
IP 20