Connecting To Gas Supply; Functional Description, Gw Models With Weishaupt Burner - Nilfisk-Advance SH SOLAR G Instructions For Use Manual

Table of Contents

Advertisement

SH SOLAR G, GH, GW
3.11 Connecting to gas
supply
3.12 Functional descrip-
tion, GW models with
Weishaupt burner
Exhaust gases
Cooling air
10
All models are equipped with a
gas burner.
An authorized gas technician
must perform connection of the
gas burner to the public gas
supply and adjust it.
Make sure that the machine
is connected to the gas sup-
ply with a fl exible, approved
hose - at least 1 m long. This
will eliminate vibrations of the
machine to the gas supply line
and hereby prevent long-term
damage to the gas line.
The fl exible hose also makes
it convenient and faster for the
Nilfi sk service represen tative to
perform service on the heating
coil / heat exchanger of the ma-
chine - not having to interrupt
the gas supply.
The gas burner burns off the
gas in a boiler. Exhaust gases
(1) are led through the funnel
(2).
The cooling fan (3) blows air in
between the outer and the inner
jacket and further on through
the funnel. The cooling air
does not enter the combustion
chamber.
NOTE: All exhaust gas
measurements must be made
in the measuring pipe (4).
Detach plug prior to measure-
ment.
If the measurements are made
above the funnel, the cooling air
will be mixed with fl ue gases.