5.1.2.9
Snap cable retention assemblies into the appropriate locations.
5.1.2.10
Secure with bolts if grounded. See photos 15-17.
Photo 15
5.1.2.11
Mark ribbon fibers 46" from the cable jacket opening on incoming signal side of cable.
5.1.2.12
Remove ribbon containing fiber to be spliced from fiber stack.
5.1.2.13
Store express fibers in storage area starting with fiber entering closure from the right side. See photo 20.
Tray stack may be removed for easier access to storage. See photos 18-20.
Photo 18
Proceed to Section 8 for Fiber organizing/storage, routing and splicing.
5.1.3
Stub.-.loose.buffer.tube.(LBT)
Inline Stub (Cable End) Configuration
5.1.3.1
Remove 55" of outer sheath from end of cable. See Figure 4.
5.1.3.2
Cut strength member(s) 1¾" from end of sheath openings. See Figure 4.
Page 10 of 37
© 2021 CommScope, Inc. All Rights Reserved
Photo 16
Photo 19
Figure 4
Photo 17
Photo 20