  • Page 1 ® -M23 SDARS 3-Sector Optical Remote Unit (M-Cabinet) Manual - Preliminary MF0150A9A...
  • Page 2 DISCLAIMER: This document has been developed by CommScope, and is intended for the use of its customers and customer support personnel. The information in this document is subject to change without notice. While every effort has been made to eliminate errors, CommScope disclaims liability for any difficulties arising from the interpretation of the information contained herein.
  • Page 3: Table Of Contents

    Optical-Fiber-Cable Connection - Rules 29  4.2.9.  Protective Plug 31  4.2.10.  Protective-Tube Kit 33  4.2.11.  External-Alarm Inputs and Outputs 34  4.2.12.  Power Connection 36  4.2.13.  Commisioning Flowchart 37  ALARMS AND TROUBLESHOOTING     MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 3...
  • Page 4   FIGURES AND TABLES figure 3-1 Block diagram ION-M23 SDARS ............... 15   figure 3-2 System overview with an ION-M23 SDARS Remote Unit ......15   figure 4-1 Wall mounting, (metric dimensions) ............18   figure 4-2 Pole-mounting kit ..................19  ...
  • Page 5: General

    Directive on Restriction of certain Hazardous Substances Remote Unit Receiver SNMP Simple Network Management Protocol Transmitter Uplink UMTS Universal Mobile Telecommunication System Uninterruptible Power Supply WCDMA Wideband Code Division Multiple Access Wavelength Division Multiplex MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 5...
  • Page 6: Health And Safety

    7. Notice: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. Page 6 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 7: Compliance

    FCC Grant and can be requested from the FCC data base, is not exceeded. The industrial boosters are shipped only as a naked booster without any installation devices or antennas as it needs for professional installation. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 7...
  • Page 8 9. Note: This unit complies with European standard EN62368-1. 10. Note: This unit must be installed in areas with restricted access for skilled employees only. Page 8 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 9 RoHS directive 2011/65/EU certified by the notified body no. 0700. Required Antenna Distances ION-M Model Antenna gain Maximum Distance   without ISED cable loss inches inches [dBi] ION-M23 SDARS .355 13.97 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 9...
  • Page 10: About Commscope

    To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions. For technical assistance and support, please also contact the local office or CommScope directly at one of the addresses listed in the following chapter. Page 10 MF0150A9A_prel.docx...
  • Page 11: International Contact Addresses For Customer Support

    Jumeirah Lakes Towers, Sandton 2146 Dubai, United Arab Emirates South Africa East Phone +971 4 390 09 80 Phone + 27 11-719-6000 +971 4 390 86 23 + 27 11-444-5393 E-mail wisupport@commscope.com E-mail wisupport@commscope.com MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 11...
  • Page 12 E-mail wisupport.ch@commscope.com Italy Iberia Region - Spain & Portugal CommScope Italy S.r.l., Faenza, Italy Andrew España S.A. A CommScope Company Via Mengolina, 20 Avda. de Europa, 4 - 2ª pta. Mail 48018 Faenza (RA) Mail Parque Empresarial de la Moraleja...
  • Page 13: Introduction

    6.7 mW. 2.2. The ION-M23 SDARS 3-Sector The ION-M23 SDARS 3-Sector is a Remote Unit configuration used in conjunction with a Master Unit, both forming an optical terrestrial repeater. This system transports signals in the frequency range 2324 to 2341.5 MHz, providing a cost-effective solution for coverage.
  • Page 14  Compliant with FCC requirement 90 + 10 log (P) dB on all frequencies outside of 2320 - 2345 MHz  Single fiber for multiple bands and multiple remotes  Easy installation and commissioning Page 14 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 15: Functional Description

    3. Functional Description 3.1. General figure 3-1 Block diagram ION-M23 SDARS figure 3-2 System overview with an ION-M23 SDARS Remote Unit 3.2. Accessory Equipment 3.2.1. Fan-Protection Kit In order to protect the fan unit (e.g. against rain), a protective cover to be mounted over the air inlet is delivered with the unit.
  • Page 16: Commissioning

     When opening the Remote Unit do not damage the warranty labels on the internal devices. The warranty is void if the seals are broken. Unless otherwise agreed to in writing by CommScope, CommScope’s general limited product warranty (http://www.commscope.com/Resources/Warranties/) shall be the warranty governing the Remote Units, including the installation, maintenance, usage and operation of the Remote Units.
  • Page 17 The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 17...
  • Page 18: Wall-Mounting Procedure

    4-1 Wall mounting, (metric dimensions) * The dowels are not part of the delivery since the suitable type depends on the on-site conditions (material of wall). Therefore, use dowels that are appropriate for the mounting surface. Page 18 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 19: Pole Mounting

    U-beam, and fasten them immediately using the washers and nuts. Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 19...
  • Page 20: Figure 4-3 Pole Mounting (Metric Dimensions)

    TESPA screw band, Form B Ø 8.0 screw band ES 119 Remote Unit stainless, 11 mm Hexagon nut M8 DIN 934 Pole Pole Pole-mounting bracket G0764M6 figure 4-3 Pole mounting (metric dimensions) Page 20 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 21: Mounting Of Fan Protection

    4-4 Mounting procedure for fan protection, (metric dimensions) This figure shows the long version of the RU. For dimensions of the short version,  see Mechanical Specifications in chapter 7.2.3 or figure 7 3. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 21...
  • Page 22: Electrical Installation

    9. Notice: For unstabilized electric networks, which frequently generate spikes, the 10. Notice: Observe the labels on the front panels before connecting or disconnecting any cables. 11. Notice: Unused connectors must be closed with their protective covers to ensure watertightness. Page 22 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 23: Connections

    Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the Remote Unit (see section 4.2.3). Do not use the grounding connection to connect external devices. figure 4-6 Grounding bolt (left) and schematic view (right) MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 23...
  • Page 24: Connection Of The Antenna Cables

     Avoid metallic abrasion when mounting the connectors by only screwing the connecting nut, but not turning the whole connector.  Use a torque wrench to fasten the connector, see above.  Clean the protective caps before mounting for antenna cable replacement. Page 24 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 25: Cleaning Procedure For Rf Cable Connectors

    Caution: Risk of injury by flying particles when compressed air is used. Wear protective clothing, especially protective glasses. 3. Remove metal chips and small particles from the mating and inner surfaces of the connector using compressed air. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 25...
  • Page 26 6. Clean the inside surface of the inner ring with a cotton bud drenched with isopropyl alcohol. 7. Clean the inside of the center conductor spring tines with a cotton bud drenched with isopropyl alcohol. Page 26 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 27 10. Continue with the winding area using lint-free wipe drenched with isopropyl alcohol. 11. Continue with the inside mating surface of the inner ring. 12. Clean the outside surface of the center pin. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 27...
  • Page 28: Antenna Cable Connector Assembly

    2. Join the connectors and turn the coupling nut until the thread grips. 3. Push in the connector until it clicks. 4. Fasten the coupling nut hand-tight. Do not turn the connector but the coupling nut only. Page 28 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 29: Optical-Fiber-Cable Connection - Rules

    The fiber-optic cables are connected to the optical transceiver.  Note: Angled connectors are not compatible with straight optical connectors; non-compatibility of connectors will result in permanent damage to both connectors. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 29...
  • Page 30 8. Repeat steps 5 through 7 until end face is clean. Note: For a more detailed description, please refer to: http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186 a0080254eba.shtml Page 30 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 31: Protective Plug

    To release the contact for disassembling, push the inner snap to the side and pull the contact out. To release upper and lower insulation bodies for disassembly, use a small screwdriver to carefully open the snap-connections at the left and right side of the insulator without damaging them. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 31...
  • Page 32 **** Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The locking ring has to be pushed forward to lock the connector and pulled back to free the connection. Page 32 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 33: Protective-Tube Kit

    Protective tube the backshell! Push the fiber-optic cable carefully through the tube until it comes out at the other end. G1055M0 figure 4-8 Tube-kit installation MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 33...
  • Page 34: External-Alarm Inputs And Outputs

    Spare Parts. Subminiature circular connectors series 712 with five and seven contacts, which are contained in the alarm kit, can be ordered directly from the Binder Connector Group, the manufacturer, or indirectly from CommScope. For the location of the external-alarm inputs and outputs see figure “Connector Flange”.
  • Page 35: Figure 4-11 Alarm Outputs (Optocoupler)

    Just wait a few minutes until the thermoswitch reaches the normal operating temperature again.  The manufacturer / supplier of this system assumes no liability for Note: damage caused by equipment connected to external outputs or by effects from such equipment. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 35...
  • Page 36: Power Connection

    For the DC power supply, observe the local regulations of the DC service provider. With the mains power turned off, the power supply plug must be connected to the Remote Unit’s mains connector. Page 36 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 37: Commisioning Flowchart

    Spanner with opening 32 Electrical connections Mains cable Connect AC power to the power cable. Connecting kit Ensure there is a circuit breaker between mains and RU. G1055Z0 Mains Switch mains power on. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 37...
  • Page 38 ALC alarm: Decrease DL input power of service affected band. VSWR alarm: Check antenna and cable. Finished setting up all RUs? Proceed to MU to set up the SW Output: Go to MU All RUs okay. Page 38 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 39: Alarms And Troubleshooting

    Master Controller).Explicit troubleshooting is also available in the MU software (software manual or WEB Interface). The connection of the external alarms inputs and outputs provided is described in chapter 4.2.11. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 39...
  • Page 40 Take care not to unintentionally damage the seals on the modules to maintain warranty. Please keep these guidelines in mind during maintenance: Unless otherwise agreed to in writing by CommScope, CommScope’s general limited product warranty (http://www.commscope.com/Resources/Warranties/) shall be the warranty governing the Remote Units, including the installation, maintenance, usage and operation of the Remote Units.
  • Page 41 6. Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8 (see step 2). In order not to exceed the specified torque of 3.3 N-m, use an appropriate tool. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 41...
  • Page 42 Take care that the material is not scratched or damaged. 5. After cleaning the heat sink, mount the fan unit again according to section 6.2 Replacing the Fan Unit step 6. Then, switch the Remote Unit back on. Page 42 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 43: Figure 7-1 Cabinet Drawing

    7. Appendix 7. Appendix 7.1. Illustrations figure 7-1 Cabinet drawing MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 43...
  • Page 44 Specifications leaflet of the supplier, related to ETS 300 019 (European Telecommunication Standard). Operating temperature range -33° C to +55° C Ingress protection IP67 All data is subject to change without notice. Page 44 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...
  • Page 45 ISO Trafo Kit 230 V Pole Mounting 7159621 Overcoat Housing Kit Pole Mounting 7159624 Alarm Kit 7157396 The manufacturer reserves the right to replace the spare parts listed above by equivalent substitutes. MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector Page 45...
  • Page 46 External-Alarm Inputs & Outputs ......34 Mechanical ............44 Status LED ............. 39 F  T  Fiber-Optical Components (Installation, Cleaning) 30 Flange Connector (7 poles) ........35 Troubleshooting ............. 39 G  Grounding (Earthing)..........23 Page 46 MF0150A9A_prel.docx Manual for ION-M23 SDARS 3-Sector...

Table of Contents