PREVOST X3-45 VIP 2017 Owner's Manual page 208

Table of Contents

Advertisement

Appendix C – Allison Diagnostic Troubleshooting Codes
12
DTC
P2730
Pressure Control Solenoid 1 (PCS1) Control Circuit High
P2736
Pressure Control Solenoid 5 (PCS5) Control Circuit Open
P2738
Pressure Control Solenoid 5 (PCS5) Control Circuit Low
P2739
Pressure Control Solenoid 5 (PCS5) Control Circuit High
Retarder Oil Temperature Sensor Over Temperature
P273F
Condition
Retarder Oil Temperature Sensor Circuit – Low
P2742
Retarder Oil Temperature Sensor Circuit – High
P2743
P2761
TCC PCS Control Circuit Open
P2763
TCC PCS Control Circuit High
P2764
TCC PCS Control Circuit Low
Transmission Clutch Life Expired (Clutch Adaptive
P2789
Learning at Limit)
P2793
Gear Shift Direction Circuit
P2808
Pressure Control Solenoid 6 (PCS6) Stuck Off
P2809
Pressure Control Solenoid 6 (PCS6) Stuck On
P2812
Pressure Control Solenoid 6 (PCS6) Control Circuit Open
P2814
Pressure Control Solenoid 6 (PCS6) Control Circuit Low
P2815
Pressure Control Solenoid 6 (PCS6) Control Circuit High
U0073 CAN Communication Bus 1 Off
U0074 CAN Communication Bus 2 Off
U0100 Lost Communications with ECM A
Lost Communication with Gear Shift Module (Shift
U0103
Selector) 1
Lost Communication with Gear Shift Module (Shift
U0291
Selector) 2
U0304 Incompatible Gear Shift Module 1 (Shift Selector)
U0333 Incompatible Gear Shift Module 2 (Shift Selector)
Invalid Data Received From Gear Shift Module (Shift
U0404
Selector) 1
Invalid Data Received From Gear Shift Module (Shift
U0592
Selector) 2
Description
CHECK
Inhibited Operation
Light
Description
Yes
DNS, SOL OFF (hydraulic default)
Yes
Inhibit retarder operation
Allow 2 through 6, N, R. Inhibit
Yes
retarder and TCC operation
Yes
Inhibit retarder operation
No
None
No
Use default retarder temp values
No
Use default retarder temp values
Yes
Inhibit TCC operation
Yes
Inhibit TCC operation
7-speed: Allow 2 through 6, N, R.
Yes
Inhibit TCC operation
No
None
Ignores PWM input from shift
Yes
selector
Yes
DNS, RPR
Yes
DNS, RPR
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
No
Use default values
No
Use default values
Yes
Use default values
Maintain range selected, observe
Yes
gear shift direction circuit
Maintain range selected, observe
Yes
gear shift direction circuit
Yes
Ignore shift selector inputs
Yes
Ignore shift selector inputs
Maintain range selected, observe
Yes
gear shift direction circuit
Maintain range selected, observe
Yes
gear shift direction circuit

Advertisement

Table of Contents
loading

Table of Contents