Alarm Settings
When selecting the Alarm Settings Menu, a sub
menu
containing
Pressure
Alarm
and
Temperature Alarm appears.
Display Settings
When selecting Pressure, the following pressure
alarm screen appears. A similar screen is
displayed for temperature settings. The cursor
can be moved to highlight the data beside "
NEW
" and the "
" option. +/- allows
/
VALUE
ACCEPT
EXIT
increasing or decreasing the "
" data.
NEW VALUE
Pressure alarm changes are done by steps of 1
PSI, in the range from 5 to 20 PSI. Temperature
alarm is done by steps of 5°F (2°C) in the range
from 150 to 180 °F (64 to 82 °C). Pressing OK
with "
" highlighted applies changes and
ACCEPT
exits to the previous menu, while pressing OK
while the "
" option is highlighted exits without
EXIT
changes.