Dimensions

578
Dimensions
Height
Width
Corpus depth
Weight
Weight without shell
Weight with shell
Storage mass
Flue pipe connection
Flue pipe outlet
Original angle pipe connection height
Original angle pipe total depth
Original angle pipe distance to rear
wall
Deapth from rear wall to middle of flue
pipe
Original angle pipe side distance
Connection height
Connection side distance
Fresh air connection
Diameter
Connection height
Side distance

Amount of fuel

Nominal load
Amount of fuel 10 kW
Amount of fuel 6 kW
*Practical values may vary depending on wood quality�

Electrical connection (Rikatronic3)

The stove is supplied with an approx� 2m long connecting cable with
a Euro-plug� This cable is to be connected to a 230Volt/50Hz socket�
The average electrical power consumption is some 4 Watt in regular
operation� The connection cable must be laid in a way that there is
no contact to any sharp edges or hot surfaces of the stove�
217
156
150
516
125
733
manual
[mm]
1193
[mm]
578
[mm]
516
manual
[kg]
160
[kg]
290
[kg]
155
manual
[mm]
150
[mm]
1711
[mm]
733
[mm]
217
[mm]
156
[mm]
289
[mm]
986
[mm]
289
manual
[mm]
125
[mm]
190
[mm]
289
Part load
~2,8 kg*
~1,4 kg*
~1,8 kg*

Technical Data

289
Description 10 kW
Nominal heat output
Partial heat output
289
Room
heating
depending
coating
Fuel consumption
Electric supply
Average electrical input
Fuse
Efficiency
CO
2
289
CO-emission on 13% O
Dust emission
Rikatr.
Exhaust
1193
Exhaust temperature
578
Chimney draft requirement
516
Description 6 kW
Rikatr.
Nominal heat output
160
Partial heat output
290
Room
heating
155
depending on house coating
Rikatr.
Fuel consumption
150
Electric supply
1711
Average electrical input
733
Fuse
Efficiency
217
CO
2
156
CO-emission on 13% O
Dust emission
289
Exhaust
986
Exhaust temperature
289
Chimney draft requirement
Rikatr.
The owner of small firing system or the person authorised for the
125
small firing system is to keep the technical documentation and is to
190
submit it to the authorities or the chimney sweep on request�
289
Note
Please observe the national and European standards as well as
local regulations concerning the installation and operation of
firing installations!

Packaging

Your first impression is important to us!
-
The packaging of your new stove provides excellent protection
against damage� However damage to the stove and accessories
may still occur during transport�
Note
Therefore please check your stove on receipt for damage and
completeness! Report any deficiencies to your dealer immediately!
Pay particular attention during unpacking that the stone panels
remain intact� Scratches to the material can easily occur� Stone
panels are excluded from the warranty�
The packaging of your new stove is environmentally neutral to a
great extent�
Tip
The wood used in the packaging has not been surface treated and
may therefore be burnt in your stove after removal of all screws
and nails� The cardboard and film (PE) can be disposed of via the
municipal waste collection for recycling�
[kW]
[kW]
capacity
on
house
[m
3
]
[kg/h]
[V]/[Hz]
[W]
[A]
[%]
[%]
[mg/m
]
3
2
N
[mg/m
3
]
N
[g/s]
[°C]
[Pa]
[kW]
[kW]
capacity
[m
]
3
[kg/h]
[V]/[Hz]
[W]
[A]
[%]
[%]
[mg/m
]
3
2
N
[mg/m
3
]
N
[g/s]
[°C]
[Pa]
manual
Rikatr.
10
10
5
5
120 - 260
120 - 260
~2,8
~2,8
-
230/50
-
~ 4
-
1,6
86
81,9
9,6
10,0
869
718
34
23
8,6
8,6
188
232
12
12
manual
Rikatr.
6
6
-
-
70 - 160
70 - 160
~1,8
~1,8
-
230/50
-
4
-
1,6
81,7
81,7
8,2
8,2
1167
1167
25,5
25,5
6,8
6,8
214,6
214,6
12
12

Advertisement