Dimensions; Amount Of Fuel; Technical Data; Packaging - RIKA E16705 Operating Manual

Hide thumbs Also See for E16705:
Table of Contents

Advertisement

Dimensions

177
206
420
177
420
177
420
Dimensions
Height
Width
Corpus depth
Weight
Weight with steelshell
Flue pipe connection
Flue pipe outlet
Original angle pipe connection height
Original angle pipe total depth
Original angle pipe distance to rear wall
Depth from rear wall to middle of flue
pipe
Original angle pipe side distance
Rear connection height
Rear connection side distance
Fresh air connection below
Diameter
Connection height optional*
Side distance
*standard with connection at the bottom
177
130
177
125
177
420
626
177
130
125
177
[mm]
1340 / 1695
[mm]
420
[mm]
420
[kg]
158
[mm]
130
[mm]
1944
[mm]
626
[mm]
206
[mm]
177
[mm]
177
[mm]
1224 / 1498
[mm]
177
[mm]
125
[mm]
144
[mm]
177
Fresh air connection left/right *
Diameter
Connection height
Side distance
177

Amount of fuel

Amount of fuel 8 kW
Amount of fuel 6 kW
* optional: E16728 Air supply adapter
** Practical values may vary depending on fuel quality�

Technical data

Technical data
Heating power range
Fresh air demand
Room heating capacity
(depending on house insulation)
Fuel consumption
Efficiency
CO
2
CO-emission on 13% O
Dust emission
Exhaust
Exhaust temperature
Chimney draft requirement
The owner of small firing systems or the person authorised for the
small firing system is to keep the technical documentation and is to
submit it to the authorities or the chimney sweep on request�
Note
Please observe the national and European standards as well as
local regulations concerning the installation and operation of
firing installations!

Packaging

Your first impression is important to us!
The packaging of your new stove provides excellent protection
against damage� However damage to the stove and accessories
may
still
Note
Therefore please check your stove on receipt for damage and
completeness! Report any deficiencies to your dealer immediately!
Pay particular attention during unpacking that the stone panels
remain intact� Scratches to the material can easily occur� Stone
panels are excluded from the warrant�
The packaging of your new stove is environmentally neutral to a
great extent�
Tip
The wood used in the packaging has not been surface treated
and may therefore be burnt in your woodburning stove (not in a
pelletstove!)� The cardboard and film (PE) can be depolluted via
the municipal waste collection for recycling�
[mm]
[mm]
[mm]
Nominal load
Part load
~2,2 kg**
~1,1 kg**
~1,8 kg**
8 kW
[kW]
4 - 8
[m
3
/h]
21
[m
]
90 - 210
3
[kg/h]
~2,2
[%]
>80%
[%]
testing
[mg/m
3
]
<1250
2
N
[mg/m
]
<40
3
N
[g/s]
~7,3
[°C]
~220
[Pa]
12
occur
during
125
144
177
-
6 kW
6
16
70-160
~1,8
>80%
testing
<1250
<40
~5,9
~200
12
transport�
|11
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

E16709E16726E16727

Table of Contents