TABLE OF CONTENTS 1. FIRST STEPS 2. OPERATION Heat up ........................................3 Heat ..........................................4 Reload ........................................4 Burn out ........................................4 ECO-mode ......................................4 3. SPECIAL FEATURES Ignition Timer ......................................4 Fully closing of the air flaps ..................................4 Child lock .........................................4 4. OVERVIEW MENU Main menu .......................................5 Setupmenu .......................................6 Infomenu ........................................7 5.
This may take up to 4 minutes. After successful verification, the display changes to the set time. The stove can now be heated. The user board of Rikatronic4 consists of the display and 4 Buttons. Function Plus On top of this first layer settle on other chipboards crosswise.
2 seconds. The display UNLOCK appears for a short time and the key lock is cancelled. Fully closing of the air flaps The Rikatronic4 has a safety device that prevents the air flaps from closing The activated ignition time is :4 5 A completely during heating (deflagration).
5. STATUS DISPLAY Display Meaning Possible reaction The test of the internal components is active (after Just wait. Do not heat the stove until the display each power-up and after a power failure). changes to the set time. Display of set time. The combustion chamber is cold and the stove is Perform fire lighting.
6. ERRORS Note The fault indicator will flash red. For recurring error messages the customer service must be informed immediately! Display Meaning Actions to be taken The automatic ignition failed. Repeat the ignition process, possibly add more chipboard or an entire block of fire lighters. Check chimney draft.
8. MANUAL OPERATION Turn the wrench counterclockwise gradually to reduce the combustion air by Power failure hand and therefore regulate the combustion process by hand. During a power failure, the air supply remains unchanged, the logs in the combustion chamber burn down safely. If the mains supply is restored, stove name and software version are displayed shortly.
Need help?
Do you have a question about the Rikatronic4 and is the answer not in the manual?