4.2.2
Replacing the transfer roller unit
A. Periodically replaced parts/cycle
• Transfer roller unit: Every 100,000 counts
B. Removal procedure
1. Open the right door.
[1]
[1]
5. To reinstall, reverse the order of removal.
6. From the Menu, select [Service Mode] → [Supplies] → [Consumables Replace] →
[Transfer Roller Unit] and execute this function to reset the transfer roller counter value.
7. From the Menu, select [Admin Setting] → [Printer Setting] → [Quality Settings] → [Gra-
dation Adjust] → [AIDC Process] and execute this function.
4. PERIODICAL MAINTENANCE PROCEDURE
2. Push two levers [1] inside to unlock
3. Rotate the transfer roller unit [2] in
[2]
A121F2C511DA
4. Remove the transfer roller unit [1].
A121F2C512DA
the transfer roller.
the direction of the arrow.
15