Performance Curve; Wiring Schemes - Danfoss MCV109A Manual

Electrical displacement control-mv
Table of Contents

Advertisement

WIRING DIAGRAM (Typical)
-V
GROUND

PERFORMANCE CURVE

18
6
OUTPUT CURRENT (mA)
03, 04, 07, 08
Current vs. Swashplate Angle for the MCV109. Legend
References the Last Two Digits of the Part Number.
BLN-95-8985-1
MCH CONTROL HANDLE
MCV104
100
200
11
01, 02, 05, 06
1446A
A
EDC
PV
B

WIRING SCHEMES

+A
B
Single coil 140 mA
with 3.3 Vdc input
at full destroke.
+A
B
C
D
Dual coils in series,
72 mA with 4.4 Vdc
input at full destroke.
Wiring Schemes Using Four Different Pilot Valve Con-
figurations for the EDC. Input Voltages Specified at
°
24
C.
4
B
MCV109
EDC
MV
A
+A
B
+C
D
Using one of the two dual coils,
185 mA with 2.8 Vdc (C, D) or
3.6 Vdc (A, B) input at full destroke.
+A
B
C
D
Dual coils in parallel,
185 mA with 1.4 Vdc
input at full destroke.
1444
1447

Advertisement

Table of Contents
loading