WIRING (continued)
To assemble the female tower connector, use the follow-
ing directions:
1.
Isolate the wires that extend from the command source
to the EDC.
2.
Strip back the insulation 5.5 millimeters on both wires.
3.
Push a ribbed cable seal over each of the wires with the
smaller-diameter shoulder of the seals toward the wire
tip. Select the pair of seals that fits tightly over the wires.
The distance from the tip of the wires to the first (nearest)
rib should be 9.5 millimeters. Thus the installation should
just protrude beyond the seal.
4.
Select the larger of the two sets of pins, as measured at
Dimension A (see Dimension A diagram), if using a 14-
16 gauge wire. Choose the smaller if using 18-20 gauge.
Place the wire into the socket so that the seal edge is
pushed through and extends slightly beyond the circular
tabs that hold it in place. Crimp in the locations shown
(see Distance, Packard Connector diagram) with a
Packard 12014254 crimp tool available from your local
Packard distributor.
DIMENSION A, PACKARD CONNECTOR
DIMENSION A
DISTANCE, PACKARD CONNECTOR
CRI MP
Distance From Tang to Third Rib of
Packard Connector.
5.
6.
7.
8.
Dimension A For Selecting Correct Terminal.
CONNECTOR PARTS IDENTIFIED,
PACKARD CONNECTOR
1 9 . 5 mm MAX .
1077A
7
The distance from the back of the tangs to the furthest
rib may not exceed 19.5 millimeters. See Distance,
Packard Connector diagram.
Manually insert the assembled wires into the back end
(large hole) of the plastic housing. Push until the wire
detents with an audible click, then pull back slightly to
ensure proper seating. (Observe the proper phasing of
the wires when installing: black wire to "A" hole, red to
"B", black to "C" and red to "D".) Terminals may be
removed from the connector bodies with a Packard
12014012 removal tool.
Swing the holder down into the detented position to trap
the wires in the housing. The third rib should be sealed
into the housing.
Plug the shroud connector from the valve into the tower
connector just constructed. They are sealed with a
double (or quadruple) plug seal over the double (or
quadruple) barrel of the tower assembly. The two con-
nector halves should detent into each other. See Con-
nector Parts Identified diagram.
SIDE "B"
CABLE
SEALS
Interlocked Connector Halves With Parts Identified.
Two Wire Connection Shown.
1123
SIDE "A"
SHROUD
CONNECTOR
DOUBLE-PLUG SEAL
TOWER CONNECTOR
1078A
BLN-95-8985-1