4000Hs Pump - Graco SaniForce 2150 Operation

Electric-operated diaphragm pump
Hide thumbs Also See for SaniForce 2150:
Table of Contents

Advertisement

Mount the
the 2150
2150 HS/3
HS/3 - - - A/PH,
Mount
Mount
the
2150
HS/3
To avoid serious injury or death from toxic fluid or
fumes:
• Never move or lift a pump under pressure. If
dropped, the fluid section may rupture. Always
follow the
Pressure Relief Procedure, page
before moving or lifting the pump.
NOTICE
NOTICE
NOTICE
The pump is heavy. To prevent damage from
dropping, always use a lift to move the pump. Do
not use the manifolds to lift the pump. Use at least
two straps.
3A5132K
All manuals and user guides at all-guides.com
A/PH, 3000HS,
3000HS, 4000HS

4000HS Pump

A/PH,
3000HS,
4000HS
21,
Pump
Pump
1. All pump models must be securely mounted
to the floor. Prior to securing, make
sure the mounting surface is flat and that
the pump base doesn't wobble. See
Dimensions (2150HS/3-A/PH Pumps), page
Dimensions (3000HS Flapper Pump), page
or
Dimensions (4000HS Flapper Pump), page
as appropriate.
NOTICE
NOTICE
NOTICE
To prevent pump damage, use all fasteners.
2. Secure the pump with screws through the
mounting bracket.
3. For ease of operation and service, mount the
pump so fluid inlet and fluid outlet ports are easily
accessible.
4. Attach the pump base to the mounting surface.
Installation
39,
41,
43,
13

Advertisement

Table of Contents
loading