2. SteamCraft Descaling Procedure Using the Descaling Pump System
Cleveland Range recommends that your service agency descales your 21CET8 and
21CET16.
If you have trained and skilled in-house maintenance personnel, you may wish to discuss
purchasing Descaling Pump System P/N: 1071421 for use with Dissolve® Descaler Solution
P/N 106174 with your sales representative or service agency.
Use no other system of descaling.
3. Manual Method to Descale Steam Generator
NOTE: Part No. 106174 is the Part No. for a case (6 1-gallon containers) of DISSOLVE
descaler.
THESE INSTRUCTIONS ARE FOR USE WITH DISSOLVE
Cleveland Range Part No. 106174.
Health Hazard Data, Effects of Overexposure
This product may cause a burning sensation to eyes or skin.
Emergency and First Aid Procedures
In case of eye contact, immediately flush eyes with water for 15 minutes. If irritation
persists seek medical attention.
In case of skin contact wash with soap and water.
If inhaled, remove to fresh air. If burning persists, call a physician.
If ingested, take 1 or 2 glasses of water and call a physician.
Spill or Leak Procedures
Rinse with plenty of water to dilute.
Sodium carbonate or calcium carbonate may be used to soak up liquid.
Considered non-hazardous, spent material may be disposed of in a sewer system with
water flush.
Do not use any other product or method of descaling other than the
DISSOLVE
Descaling procedure is slightly different depending on model. This
entire procedure should be read and fully understood as it applies to
the model being descaled, before beginning descaling operations.
CAUTION
®
Descaler method using Part No. 106174.