6.
Timed Test 2: Start timing upon pressing the MANUAL end of the TIMED/MANUAL Switch.
Press the MANUAL end of the TIMED/MANUAL Switch
a. Immediately:
The condenser solenoid clicks open and condenser flow starts.
•
The heater coil turns on when the water level in the float/probe assembly cylinder is
•
1 inch from the bottom of the cylinder.
b. 2-5 Seconds:
A small stream of water flows from the drainpipe. If no water flows, make sure the water
•
supply valves are open.
c. 2 Minutes:
A dull roaring sound indicates the heater is working and steam is being produced.
•
d. 3-4 Minutes:
Steam begins to enter the cooking compartment through the nozzles. (A small amount of
•
water may drip from the nozzles until steam clears the lines.)
e. 4-5 Minutes:
Steam from the nozzles begins to fill the cooking compartment.
•
20