Cleveland SteamCraft 21CET8 Operation Installation Maintenance Manual page 19

Electric convection steamers
Hide thumbs Also See for SteamCraft 21CET8:
Table of Contents

Advertisement

a. The water supply must have a minimum dynamic (flow) pressure of 35 psi (2.4 kg/cm²)
and a maximum static pressure of 60 psi (4.1 kg/cm²).
b. If the static pressure is above 60 psi, a pressure regulator must be used and set at
approximately 50 psi. Pressure above 60 psi can damage solenoid valves.
c. SteamCrafts have two ¾" garden hose connection points for incoming water: condenser, and
generator.
d. If the water supply meets requirements shown in the Warranty then the Single Water Supply
Arrangement shown in Figure 3-2 may be used.
If using a single water feed to the system the supply piping to the tee fitting should be at
least the next larger size of pipe than the connection provided on the SteamCraft.
e. If the water supply fails to meet the requirements shown in the Warranty then use the
Separate Water Supply Arrangement shown in Figure 3-3.
f.
Installation Requirements:
1)
Apply non-hardening pipe sealant to all the threaded connections,
(EXCEPT FOR GARDEN HOSE TYPE THREAD).
2)
Install a manual water shut-off valve (not provided) between main cold
water supply line(s) and SteamCraft supply lines.
3)
This steamer must be installed with adequate backflow prevention in all
supply lines, to comply with federal, state, or local codes having
jurisdiction.
4)
NOTE: Do not remove the filter washers from the garden hose thread
fittings
5)
Construct all supply lines up to the point of installing the strainer.
6)
Flush the water supply lines before connecting the lines to the appliance.
SteamCraft
Condenser
Steam Generator
Figure 3-2 Cleveland Range Single Water Supply Arrangement
SteamCraft
Condenser
Steam Generator
Figure 3-3 Cleveland Range Separate Water Supply Arrangement
"Conditioned" indicates water that has been filtered or treated by a Cleveland Range approved
method to meet or exceed the water quality standards in the Warranty.
Air/Water Column
( if required)
Check Valve
Pressure Reducer
( if required)
Check Valve
Air/Water Column
( if required)
Pressure Reducer
( if required)
13
Figure 3-1 Filter
Washer Assembly
(P/N 110987)
Main Cold
Water Supply
Main Water
Shut Off Valve
Standard Cold
Water Supply
Main Water
Shut Off Valve
Conditioned Cold
Water Supply*