TIMED/MANUAL Switch is TIMED.
The Timer is zeroed, with the dial pointing to the 0 mark.
5.
If the Timer is not zeroed, turn the dial counterclockwise until it points to the 0 mark.
6.
Timed Test 1 Start timing upon turning the ON/OFF Switch to ON.
Turn the ON/OFF Switch ON.
a. Immediately:
The red ON/OFF Switch light turns on.
The fill valve opens and the steam generator fills with water.
The buzzer sounds for 3 seconds.
b. 3 Minutes
Water appears in the bottom of the float/probe assembly cylinder as the steam
generator fills.
NO water flows from the drainpipe.
Check for plumbing leaks.
c. 4 Minutes
The fill valve closes with a clicking sound.
The water level in the float/probe assembly cylinder stops rising about an inch from the
top of the cylinder. If the water continues to rise, STOP, shut down, and call your qualified
Cleveland Range authorized Service Representative.
7.
Timed Test 2: Start timing upon pressing the MANUAL end of the TIMED/MANUAL Switch.
Press the MANUAL end of the TIMED/MANUAL Switch
f.
Immediately:
The condenser solenoid clicks open and condenser flow starts.
The heater coil turns on when the float/probe assembly cylinder water level is 1 inch from
the bottom of the float/probe assembly cylinder.
g. 2-5 Seconds:
A small stream of water flows from the drainpipe. If no water flows make sure the water
supply valves are open.
h. 2 Minutes:
A dull roaring sound indicates the heater is working and steam is being produced.
i.
3-4 Minutes:
Steam begins to enter the cooking compartment through the nozzles. (A small amount of
water may drip from the nozzles until steam clears the lines.)
j.
4-5 Minutes:
Steam from the nozzles begins to fill the cooking compartment.
8.
Timed Test 3: Zero the Timer and start timing upon pressing the TIMED end of the
TIMED/MANUAL Switch.
Press the TIMED end of the TIMED/MANUAL Switch
a. Immediately:
The heater turns OFF.
The condenser flow stops.
The buzzer sounds for 3 seconds.
b. 30 Seconds:
Steam stops entering the cooking compartment.
9.
Open the cooking compartment door for 2-3 minutes to allow it to cool slightly.
10.
Close the cooking compartment door and continue testing.