Adjustment
1.
Open the platform-side door in the control panel.
2.
Switch on the power with the main power switch key.
3.
Load the platform with 230 kg according to the testing
instruction.
4.
Adjust the point where the platform load signal lamp is
switched on as follows.
5.
Press Reset once and then simultaneous Arrow Down
and C, until the display shows FSET. See illustrations below.
Arrow "down"
6.
Browse with arrow keys up or down until the display shows LEV2.
7.
Press key E to see the set value.
8.
Press arrow up to increase the value, arrow down to decrease the value. If the signal
lamp lights up too early, increase the value, if too late, decrease the value. Note: The
shown amount of kilograms is not directly correct set value due to the lever relations.
However the displayed value can be used as a guide value when performing the
adjustment. If the signal lamp lights up approx. 20 kg too late, reduce the shown value with
20 kg.
9.
When the value is correct, press E to accept the new value.
10. If you want to adjust also the overload alarm limit, press arrow keys to show LEV3; if
you want to exit the setting menus, press C.
11. The overload alarm and the movement switch-off value are changed as instructed in
setting 8.
12. Press E.25 to acknowledge the new value.
13.
Press C to exit the settings menu.
14.
Test the operation, repeat the setting procedure as required.