RDZ UC 500-MHE Technical Installation Manual page 15

Air handling units/ residential dehumidifier with vmc system
Table of Contents

Advertisement

UC 500-MHE – INSTALLATION, USE AND MAINTENANCE MANUAL
HEAT RECOVERY BYPASS
INDOOR
WINTER OPERATING MODE
FRESH AIR VENTILATION
INDOOR
AIR RECIRCULATION
INDOOR
Both fans are running, the
intake air damper is closed and
the bypass damper is open.
The inflow air is warmed up by
the water coil.
The air flow rate can be set
OUTDOOR
from 160 to 300 m³/h.
Both fans are running and
carrying out the fresh air
ventilation; the outdoor air is
warmed up by the heat
exchanger first, by using the
exhaust air, and then by the
hot water circulating in the
OUTDOOR
finned coil.
The supply fan is running; the
room
supplied to the room again at
the
outgoing
regulated by modulating the
OUTDOOR
flow rate of the hot water
circulating in the finned coil.
The flow rate for the supply
air can be set from 300 to 500
m³/h
air
extracted
set
temperature.
temperature
and
The
is
13 