2.40

SetFrameRate

Description:
Parameters:
VI:
Related functions
© 2010 Thorlabs
Using
, you can set the desired number of frames per second at which
SetFrameRate
the sensor works. If the frame rate is set too high, it is no longer possible to capture
every image, which means that the actual frame rate decreases. Similarly to exposure
time, only certain values can be set here; therefore, the new frame rate is returned in the
new FPS parameter when this function is used.
Camera Handle In/Out
FPS
new FPS
error in/out
45
SetExposureTime
54
SetPixelClock
GetFramesPerSecond
GetFrameTimeRange
SetAutoParameter
Handle on camera
Desired number of frames per second
Returns the actually set frame rate
Error code