Scientific Grade Digital Camera Chapter 1: Warning Symbol Definitions Warning Symbol Definitions Chapter 1 Below is a list of warning symbols you may encounter in this manual or on your device. Symbol Description Direct Current Alternating Current Both Direct and Alternating Current Earth Ground Terminal Protective Conductor Terminal Frame or Chassis Terminal...
Opening the device will void your warranty. Any modification or servicing of this system by unqualified personnel renders Thorlabs free of any liability. This device can only be returned when packed into the complete original packaging, including all foam packing inserts. If necessary, ask for replacement packaging.
Although the system is easily adapted for custom interfaces, to achieve the listed specifications, this system should only be used with accessories provided by Thorlabs. Any modification or servicing by unqualified personnel renders the warranty null and void, leaving Thorlabs free of liability. Please contact Thorlabs for questions on customization.
(Gigabit Ethernet (-GE), Camera Link (-CL), or USB 3.0 (-USB)) and whether or not a thermoelectric cooler is used (-TE for 8051, 4070, and 1501 only). Color sensors are available in the 8051C, 4070C, and 1501C models as well.
Auxiliary I/O Patch cable – The auxiliary connector on the camera allows the user to access optional camera control and internal status signals (see section 4.7). Order Thorlabs 8050-CAB1 and TSI-IOBOB or TSI-IOBOB2. ITN000081-D02 Rev. R 07/23/2018 Page 5...
Scientific Grade Digital Camera Chapter 4: Setup & Installation Setup & Installation Chapter 4 4.1. Pre-Installation Before proceeding with installation of hardware or software, please identify whether your camera interface is Camera Link, Gigabit Ethernet (GigE), or USB 3.0. 4.1.1. Gigabit Ethernet (GigE) System If you purchased a Gigabit Ethernet camera, an Intel PCIe adapter card is provided for use on desktop computer systems.
4.2. Installing the Software The Thorlabs camera software runs on Windows 7, 8.1, and 10 operating systems ONLY. 4.2.1. Load the Distribution Disk A CD or DVD disk can be found with the camera. Load the disk into the CD/DVD drive on the computer you wish to operate the camera and software.
Page 12
Scientific Grade Digital Camera Chapter 4: Setup & Installation Click Next to proceed with the driver installation. Depending on your PC’s configuration and the drivers you selected, you might encounter the additional Windows security dialogs below. Be sure to click “install” to complete the operation, otherwise the installer will “roll back”...
Page 13
Once setup is complete, you may now proceed to the next section that will describe how to connect and power on your camera. When the camera is connected and powered up, you can navigate to the ThorCam Imaging Software as shown below “Start”→”All Programs”→”ThorIabs” →”Scientific Imaging ”→”ThorCam” Figure 2 Thorlabs Installed Items ITN000081-D02 Rev. R 07/23/2018 Page 9...
To use the MATLAB and LabVIEW interfaces, extract from the Zip file and place in the appropriate directory on your system. Special note for users of Micro-manager software: support for Thorlabs scientific cameras is included when you run versions 1.4.14 and later. If you wish to download or update your Micro-Manager software, please visit https://micro-manager.org/wiki/Micro-Manager_Open_Source_Microscopy_Software...
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.3. Connecting the Camera To connect the camera, follow the steps and refer to the diagram below. 1. With the power supply turned off, connect the power supply to the “POWER” connector on the back of the camera.
Page 16
Scientific Grade Digital Camera Chapter 4: Setup & Installation If you are utilizing a Camera Link Cable: Connect one end of the Camera Link cable into the port labeled “CL 0”. Connect the other end into the port labeled “0” of the EDT VisionLink F4 Camera Link card, installed in the computer.
Ethernet Driver installation tool from the Start Menu illustrated in Figure 2. When launched, the following diagram will appear Note that USB3 Vision is not installed, even if you have a Thorlabs USB 3.0 camera, as Thorlabs cameras use a separate USB 3.0 driver. Do not install the USB3 Vision driver.
Page 18
Scientific Grade Digital Camera Chapter 4: Setup & Installation ITN000081-D02 Rev. R 07/23/2018 Page 14...
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.3.2. Multiple Camera Operation If multiple camera operation is required, it is recommended that a Gigabit Ethernet switch topology be setup, as shown below. When multiple cameras are connected and powered on, they will be visible in the Image Detector dropdown of Hardware Setup panel.
For the best results, the use of a C-Mount lens that matches the optical format of the 4/3” (22mm) imaging area is recommended. For more information on Thorlabs C-Mount lenses, please visit www.thorlabs.com C-mount lenses are specified with a flange focal distance of 17.5 mm. However, there can be considerable variation in the flange focal distance among commercially available lenses.
Four 1/4”-20 tapped holes are provided, one on each side of the housing. These may be used with tripods, or other optical mounting devices. These 1/4”-20 tapped holes are compatible with Thorlabs 1/2” posts. For more information on Thorlabs Ø1/2" posts, please visit www.thorlabs.com.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.5. Optical Front End The images below show the components located on the front end of the camera. Figure 11 Exploded View of Optical and Mechanical Components Figure 12 Optical and Mechanical Sub-Assemblies C-Mount Adapter and Lock Nut Filter Retaining...
Scientific Grade Digital Camera Chapter 4: Setup & Installation Figure 14 Reverse View of IR Filter Sub-Assembly. Shows the Lens Cap Used as a Tool for Installing and Removing the Filters 4.5.1. Description of Components C-Mount Adapter: Allows the camera to be optically coupled with standard C-mount optics, including lenses and microscope adapters.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.6. Optical Front End Procedures 4.6.1. Removing the C-mount Lock Ring Assembly Removal of the C-mount lock lens ring is not required for normal operation. It is required if users wish to remove, replace, or clean the installed filter.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.6.2. Filter Removal and Replacement Procedure TSI cameras are typically provided with an IR-blocking filter installed. The CCD has responsivity into the Near Infrared (for more details refer to specifications sections near the end of this document). If near-infrared sensitivity is desired, the IR-blocking filter should not be installed.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.6.3. Re-assembly of the C-mount Lock Ring and Flange Focus Adjustment 1. Install C-mount ring adapter into the front side of the camera as shown in Figure 18. Do NOT tighten or lock. 2.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.7. Auxiliary Connector The auxiliary connector on the camera allows the user to access optional camera control and internal status signals. 4.7.1. Pin Descriptions Pin Descriptions Pin # Signal Reserved Reserved Reserved STROBE_OUT TRIGGER_IN...
FCC compliance. The mating connector for the rear panel connector is HIROSE HR10-10P-12P (73). A 10 foot long (3m) auxiliary I/O cable and interconnect break-out board are available from Thorlabs allowing access to some of the I/O control functions (Trigger_In, Trigger_Out, LVAL_Out, FVAL_Out, and Strobe_Out).
Operation Chapter 5 The 8051/4070/1501/340-series cameras can be operated using the ThorCam and ThorImageLS (Offered separately by Thorlabs Imaging Systems). For more details on using ThorCam and ThorImageLS features, please consult the ThorCam and ThorImageLS User Manuals. 5.1. Starting the Camera With the camera software installed and the camera connected as instructed, turn on the camera power supply.
Scientific Grade Digital Camera Chapter 6: 8051M Specifications 8051M Specifications Chapter 6 6.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-08051-AXA-JD-BA Number of Active Pixels 3296 (H) x 2472 (V) 5.5 m X 5.5 m Pixel Size 4/3”...
Scientific Grade Digital Camera Chapter 6: 8051M Specifications 6.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 40 MHz 1 ms Exposure Time 20 MHz Full Sensor (3296 x 2472) 2.3 fps 4.5 fps 4.4 fps 8.5 fps 8.8 fps 17.1 fps...
Scientific Grade Digital Camera Chapter 7: 8051C Specifications 8051C Specifications Chapter 7 7.1. Color CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-08051-FXA-JD-BA Number of Active Pixels 3296 (H) x 2472 (V) 5.5 m X 5.5 m Pixel Size 4/3”...
Scientific Grade Digital Camera Chapter 7: 8051C Specifications 7.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 40 MHz 1 ms Exposure Time 20 MHz Full Sensor (3296 x 2472) 2.3 fps 4.5 fps 4.4 fps 8.5 fps 8.8 fps 17.1 fps...
Scientific Grade Digital Camera Chapter 8: 4070M Specifications 4070M Specifications Chapter 8 8.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-04070M Number of Active Pixels 2048 (H) x 2048 (V) 7.4 m X 7.4 m Pixel Size 4/3”...
Scientific Grade Digital Camera Chapter 8: 4070M Specifications 8.4. Example Frame Rates Example Frame Rates One Tap Two Tap Four Tap 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor (2048 x 2048) 4.1 fps 7.7 fps 7.4 fps...
Scientific Grade Digital Camera Chapter 9: 4070C Specifications 4070C Specifications Chapter 9 9.1. Color CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-04070-FBA Number of Active Pixels 2048 (H) x 2048 (V) 7.4 m X 7.4 m Pixel Size 4/3”...
Scientific Grade Digital Camera Chapter 9: 4070C Specifications 9.4. Example Frame Rates Example Frame Rates One Tap Two Tap Four Tap 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor (2048 x 2048) 4.1 fps 7.7 fps 7.4 fps...
Scientific Grade Digital Camera Chapter 10: 340M Specifications Chapter 10 340M Specifications 10.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi/Truesense KAI-0340 Number of Active Pixels 640 (H) x 480 (V) 7.4 m X 7.4 m Pixel Size 1/3”...
Scientific Grade Digital Camera Chapter 11: 1501M Specifications Chapter 11 1501M Specifications 11.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number Sony ICX285AL Number of Active Pixels 1392 (H) x 1040 (V) 6.45 m X 6.45 m Pixel Size 2/3”...
Scientific Grade Digital Camera Chapter 11: 1501M Specifications 11.3. Imaging Specifications Imaging Specifications Exposure Time 0 to 1000 seconds in 1 ms increments* CCD Pixel Clock Speed 20 MHz or 40 MHz ADC Resolution 14 bits (All I/O Types) ADC Gain 0 to 1023 counts Optical Black Clamp 0 to 1023 counts...
Scientific Grade Digital Camera Chapter 12: 1501C Specifications Chapter 12 1501C Specifications 12.1. Color CCD Specifications CCD Specifications CCD Manufacturer and Item Number Sony ICX285AQ Number of Active Pixels 1392 (H) x 1040 (V) 6.45 m X 6.45 m Pixel Size 2/3”...
Scientific Grade Digital Camera Chapter 12: 1501C Specifications 12.4. Example Frame Rates Example Frame Rates @ 20 MHz 40 MHz 1 ms Exposure Time Full Sensor (1392 x 1040) 12 fps 23 fps Full Sensor, Bin by 2 (696 x 520) 23 fps 41 fps Full Sensor, Bin by 10 (139 x 104)
Scientific Grade Digital Camera Chapter 13: IR Blocking Filter Chapter 13 IR Blocking Filter Figure 23 IR Blocking Filter Dimensions FESH0700 Figure 24 IR Blocking Filter Transmission Curve FESH0700 ITN000081-D02 Rev. R 07/23/2018 Page 42...
Scientific Grade Digital Camera Chapter 15: Troubleshooting Chapter 15 Troubleshooting 15.1. Interface Problem Symptoms Possible Cause Remedy 1. Power supply not 1. Plug in power supply to outlet No power to connected camera Green light on Camera does not power supply acquire image 2.
Camera is not in software 2. Enable TE-cooling in software not feel warm at warm or feels cold (8051/4070/1501-xx-TE (8051/4070/1501-xx-TE models only) to the touch models only) 3. Camera was dropped or otherwise subjected to 3. Contact customer service unusual mechanical force 1.
Scientific Grade Digital Camera Chapter 15: Troubleshooting 15.4. Software Problem Symptoms Possible Cause Remedy 1. Make sure power supply is switched 1. Power not on 2. Make sure the power and signal 2. Not plugged in cables are connected 3.
Doing so will void the warranty. If it is suspected that the seal has been broken or if the window breaks, call your local Thorlabs office or distributor. Do not apply power to the camera. Moisture will have been introduced into the chamber, and cooling in the presence of moisture will cause condensation and frost on the CCD, which can damage the entire cooling unit and/or CCD.
Re-examine once again and repeat the process once, if necessary. If contamination continues to be a problem, please call Thorlabs for assistance. CAUTION Ethyl and isopropyl alcohols are highly flammable! Do not use near extreme heat, arcing electrical equipment (such as space heaters) or open flame! Use only with proper ventilation.
17.1. Waste Treatment is Your Own Responsibility If you do not return an “end of life” unit to Thorlabs, you must hand it to a company specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.
Scientific Grade Digital Camera Chapter 17: Regulatory 17.3. Certifications and Compliance – CE Declaration of Conformity ITN000081-D02 Rev. R 07/23/2018 Page 53...
Page 58
Scientific Grade Digital Camera Chapter 17: Regulatory ITN000081-D02 Rev. R 07/23/2018 Page 54...
Page 59
Scientific Grade Digital Camera Chapter 17: Regulatory ITN000081-D02 Rev. R 07/23/2018 Page 55...
Page 60
Scientific Grade Digital Camera Chapter 17: Regulatory ITN000081-D02 Rev. R 07/23/2018 Page 56...
Scientific Grade Digital Camera Chapter 17: Regulatory 17.4. FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Chapter 18 Warranty 18.1. General Product Warranty Thorlabs warrants that all products sold will be free from defects in material and workmanship, and will conform to the published specifications under normal use, when correctly installed and maintained. 18.2. Specific Warranties 18.2.1.
Scientific Grade Digital Camera Chapter 19: Thorlabs Worldwide Contacts Chapter 19 Thorlabs Worldwide Contacts www.thorlabs.com/contact For technical support or sales inquiries, please visit us at for our most up-to- date contact information. ITN000081-D02 Rev. R 07/23/2018 Page 59...