Scientific Grade Digital Camera Chapter 1: Warning Symbol Definitions Warning Symbol Definitions Chapter 1 Below is a list of warning symbols you may encounter in this manual or on your device. Symbol Description Direct Current Alternating Current Both Direct and Alternating Current Earth Ground Terminal Protective Conductor Terminal Frame or Chassis Terminal...
Opening the device will void your warranty. Any modification or servicing of this system by unqualified personnel renders Thorlabs free of any liability. This device can only be returned when packed into the complete original packaging, including all foam packing inserts. If necessary, ask for replacement packaging.
Although the system is easily adapted for custom interfaces, to achieve the listed specifications, this system should only be used with accessories provided by Thorlabs. Any modification or servicing by unqualified personnel renders the warranty null and void, leaving Thorlabs free of liability. Please contact Thorlabs for questions on customization. ITN000081-D02 Rev. V 2/27/2020...
Failure to do so can result in the carrier refusing to honor the claim. To return your camera to TSI for service, you must first contact your local Thorlabs office or distributor and request a Return Material Authorization (RMA). Returns will not be accepted without an RMA. See Chapter 19, titled “Warranty Information”...
3.3.1. Optional Items Auxiliary I/O Patch cable – The auxiliary connector on the camera allows the user to access optional camera control and internal status signals (see 4.8). Order Thorlabs 8050-CAB1 and TSI-IOBOB or TSI-IOBOB2. ITN000081-D02 Rev. V 2/27/2020 Page 5...
Scientific Grade Digital Camera Chapter 4: Setup & Installation Setup & Installation Chapter 4 4.1. Pre-Installation Before proceeding with installation of hardware or software, please identify whether your camera interface is Camera Link, Gigabit Ethernet (GigE), or USB 3.0. 4.1.1. Gigabit Ethernet (GigE) System If you purchased a Gigabit Ethernet camera, an Intel PCIe adapter card is provided for use on desktop computer systems.
4.2. Installing the Software The Thorlabs camera software runs on Windows 7, 8.1, and 10 operating systems ONLY. 4.2.1. Load the Distribution Disk A CD or DVD disk can be found with the camera. Load the disk into the CD/DVD drive on the computer you wish to operate the camera and software.
Page 13
Scientific Grade Digital Camera Chapter 4: Setup & Installation Click Next to proceed with the driver installation. Depending on your PC’s configuration and the drivers you selected, you might encounter the additional Windows security dialogs below. Be sure to click “install” to complete the operation, otherwise the installer will “roll back”...
Page 14
Once setup is complete, you may now proceed to the next section that will describe how to connect and power on your camera. When the camera is connected and powered up, you can navigate to the ThorCam Imaging Software as shown below “Start”→”All Programs”→”ThorIabs” →”Scientific Imaging ”→”ThorCam” Figure 2 Thorlabs Installed Items ITN000081-D02 Rev. V 2/27/2020 Page 9...
To use the MATLAB and LabVIEW interfaces, extract from the Zip file and place in the appropriate directory on your system. Special note for users of Micro-manager software: support for Thorlabs scientific cameras is included when you run versions 1.4.14 and later. If you wish to download or update your Micro-Manager software, please visit https://micro-manager.org/wiki/Micro-Manager_Open_Source_Microscopy_Software...
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.3. Connecting the Camera To connect the camera, follow the steps and refer to the diagram below. 1. With the power supply turned off, connect the power supply to the “POWER” connector on the back of the camera.
Page 17
Scientific Grade Digital Camera Chapter 4: Setup & Installation If you are utilizing a Camera Link Cable: Connect one end of the Camera Link cable into the port labeled “CL 0”. Connect the other end into the port labeled “0” of the EDT VisionLink F4 Camera Link card, installed in the computer.
Ethernet Driver installation tool from the Start Menu illustrated in Figure 2. When launched, the following diagram will appear Note that USB3 Vision is not installed, even if you have a Thorlabs USB 3.0 camera, as Thorlabs cameras use a separate USB 3.0 driver. Do not install the USB3 Vision driver.
Page 19
Scientific Grade Digital Camera Chapter 4: Setup & Installation ITN000081-D02 Rev. V 2/27/2020 Page 14...
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.3.2. Multiple Camera Operation If multiple camera operation is required, it is recommended that a Gigabit Ethernet switch topology be setup, as shown below. When multiple cameras are connected and powered on, they will be visible in the Image Detector dropdown of Hardware Setup panel.
C-Mount lens that matches the optical format of the 4/3” (22mm) imaging area is recommended. For more information on Thorlabs C-Mount lenses, please visit www.thorlabs.com C-mount lenses are specified with a flange focal distance of 17.5 mm. However, there can be considerable variation in the flange focal distance among commercially available lenses.
All models have four 1/4”-20 tapped holes, one on each side of the housing. These may be used with tripods, or other optical mounting devices. These 1/4”-20 tapped holes are compatible with Thorlabs 1/2” posts. For more information on Thorlabs Ø1/2" posts, please visit www.thorlabs.com.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.5. S805MU1 No Sensor Face Plate Camera with Wedged Window These cameras contain special sensors with the protective window removed leaving the bare focal plane array exposed. These cameras are manufactured in a clean room to avoid contaminates from entering the camera. This camera contains no user serviceable parts.
Scientific Grade Digital Camera Chapter 4: Setup & Installation C-Mount Adapter and Lock Nut Filter Retaining Ring IR Blocking Filter Lens Cap (and Filter Removal Tool) Figure 13 Reverse View Showing IR Filter and Associated Components Figure 14 Reverse View of IR Filter Sub-Assembly. Shows the Lens Cap Used as a Tool for Installing and Removing the Filters 4.6.1.
Optical Front End Procedures The discussion in this section applied only to camera models 8051, 4070, 1501, and 340. The front end of S805 model cameras should never be disassembled as this could result in catastrophic damage to the sensor.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.7.2. Filter Removal and Replacement Procedure TSI cameras are typically provided with an IR-blocking filter installed. The CCD has responsivity into the Near Infrared (for more details refer to specifications sections near the end of this document). If near-infrared sensitivity is desired, the IR-blocking filter should not be installed.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.7.3. Re-assembly of the C-mount Lock Ring and Flange Focus Adjustment 1. Install C-mount ring adapter into the front side of the camera as shown in Figure 18. Do NOT tighten or lock. 2.
Scientific Grade Digital Camera Chapter 4: Setup & Installation 4.8. Auxiliary Connector The auxiliary connector on the camera allows the user to access optional camera control and internal status signals. 4.8.1. Pin Descriptions Pin Descriptions Pin # Signal Reserved Reserved Reserved STROBE_OUT TRIGGER_IN...
FCC compliance. The mating connector for the rear panel connector is HIROSE HR10-10P-12P (73). A 10 foot long (3m) auxiliary I/O cable and interconnect break-out board are available from Thorlabs allowing access to some of the I/O control functions (Trigger_In, Trigger_Out, LVAL_Out, FVAL_Out, and Strobe_Out). Order the “8050-CAB1”...
Operation Chapter 5 The S805/8051/4070/1501/340-series cameras can be operated using the ThorCam and ThorImageLS (Offered separately by Thorlabs Imaging Systems). For more details on using ThorCam and ThorImageLS features, please consult the ThorCam and ThorImageLS User Manuals. 5.1. Starting the Camera With the camera software installed and the camera connected as instructed, turn on the camera power supply.
6.2. Responsivity The sensor face plate and IR-blocking filter are removed in the S805 model cameras. A fixed wedged window is the only optic in front of the sensor, and it should never be removed. See 4.5 for more information.
Scientific Grade Digital Camera Chapter 6: S805M Specifications 6.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor 2.3 fps 4.5 fps 4.4 fps...
Scientific Grade Digital Camera Chapter 6: S805M Specifications Wedged Window: 400 - 700 nm AR Coating 0° AOI 10° AOI 20° AOI 30° AOI 45° AOI Wavelength (nm) 6.6. S805MU2 Wedged Window ITN000081-D02 Rev. V 2/27/2020 Page 30...
Page 36
Scientific Grade Digital Camera Chapter 6: S805M Specifications WW11050-C13 Wedged Window Specifications AR Coating Range 700 - 1100 nm Reflectance over AR Coating Range < 0.5% per Surface; Both Sides are Coated Wedge Angle 30 ± 10 arcmin Diameter 1" Diameter Tolerance +0.0 / -0.2 mm ≥Ø22.86 mm...
Scientific Grade Digital Camera Chapter 7: 8051M Specifications 8051M Specifications Chapter 7 7.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number 8051 On Semi KAI-08051-AXA-JD-BA Number of Active Pixels 3296 (H) x 2472 (V) Pixel Size 5.5 µm x 5.5 µm Optical Format 4/3ʺ...
Scientific Grade Digital Camera Chapter 7: 8051M Specifications 7.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor (3296 x 2472) 2.3 fps 4.5 fps 4.4 fps...
Scientific Grade Digital Camera Chapter 8: 8051C Specifications 8051C Specifications Chapter 8 8.1. Color CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-08051-FXA-JD-BA Number of Active Pixels 3296 (H) x 2472 (V) Pixel Size 5.5 µm x 5.5 µm Optical Format 4/3ʺ...
Scientific Grade Digital Camera Chapter 8: 8051C Specifications 8.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor (3296 x 2472) 2.3 fps 4.5 fps 4.4 fps...
Scientific Grade Digital Camera Chapter 9: 4070M Specifications 4070M Specifications Chapter 9 9.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-04070M Number of Active Pixels 2048 (H) x 2048 (V) Pixel Size 7.4 µm x 7.4 µm Optical Format 4/3ʺ...
Scientific Grade Digital Camera Chapter 9: 4070M Specifications 9.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor (2048 x 2048) 4.1 fps 7.7 fps 7.4 fps...
Scientific Grade Digital Camera Chapter 10: 4070C Specifications Chapter 10 4070C Specifications 10.1. Color CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi KAI-04070-FBA Number of Active Pixels 2048 (H) x 2048 (V) Pixel Size 7.4 µm x 7.4 µm 4/3”...
Scientific Grade Digital Camera Chapter 10: 4070C Specifications 10.4. Example Frame Rates One Tap Two Tap Four Tap Example Frame Rates @ 1 ms Exposure Time 20 MHz 40 MHz 20 MHz 40 MHz 20 MHz 40 MHz Full Sensor (2048 x 2048) 4.1 fps 7.7 fps 7.4 fps...
Scientific Grade Digital Camera Chapter 11: 340M Specifications Chapter 11 340M Specifications 11.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number On Semi/Truesense KAI-0340 Number of Active Pixels 640 (H) x 480 (V) Pixel Size 7.4 µm x 7.4 µm Optical Format 1/3ʺ...
Scientific Grade Digital Camera Chapter 12: 1501M Specifications Chapter 12 1501M Specifications 12.1. CCD Specifications CCD Specifications CCD Manufacturer and Item Number Sony ICX285AL Number of Active Pixels 1392 (H) x 1040 (V) Pixel Size 6.45 µm x 6.45 µm Optical Format 2/3ʺ...
Scientific Grade Digital Camera Chapter 12: 1501M Specifications 12.3. Imaging Specifications Imaging Specifications Exposure Time 0 to 1000 seconds in 1 ms Increments* CCD Pixel Clock Speed 20 MHz or 40 MHz ADC Resolution 14 bits (All I/O Types) ADC Gain 0 to 1023 Counts Optical Black Clamp 0 to 1023 Counts...
Scientific Grade Digital Camera Chapter 13: 1501C Specifications Chapter 13 1501C Specifications 13.1. Color CCD Specifications CCD Specifications CCD Manufacturer and Item Number Sony ICX285AQ Number of Active Pixels 1392 (H) x 1040 (V) Pixel Size 6.45 µm x 6.45 µm Optical Format 2/3ʺ...
Scientific Grade Digital Camera Chapter 13: 1501C Specifications 13.4. Example Frame Rates Example Frame Rates 20 MHz 40 MHz @ 1 ms Exposure Time Full Sensor (1392 x 1040) 12 fps 23 fps Full Sensor, Bin by 2 (696 x 520) 23 fps 41 fps Full Sensor, Bin by 10 (139 x 104)
Scientific Grade Digital Camera Chapter 14: IR Blocking Filter Chapter 14 IR Blocking Filter Figure 23 IR Blocking Filter Dimensions FESH0700 Figure 24 IR Blocking Filter Transmission Curve FESH0700 ITN000081-D02 Rev. V 2/27/2020 Page 46...
Scientific Grade Digital Camera Chapter 15: Mechanical Drawings 15.7. S805MU Figure 25 Schematic Showing Reduced Etalon Effects When Using a Wedged Window ITN000081-D02 Rev. V 2/27/2020 Page 50...
Scientific Grade Digital Camera Chapter 16: Troubleshooting Chapter 16 Troubleshooting 16.1. Interface Problem Symptoms Possible Cause Remedy 1. Power supply not 1. Plug in power supply to outlet No power to connected camera Green light on Camera does not power supply acquire image 2.
Scientific Grade Digital Camera Chapter 16: Troubleshooting 16.2. Optical Problem Symptoms Possible Cause Remedy When using a standard C-mount lens Displayed image is 1. Back focus of camera 1. See 4.6 on how to set the camera’s back focus (not included), not in focus needs to be set...
Scientific Grade Digital Camera Chapter 16: Troubleshooting 16.4. Software Problem Symptoms Possible Cause Remedy 1. Make sure power supply is switched 1. Power not on 2. Make sure the power and signal 2. Not plugged in cables are connected 3.
Doing so will void the warranty. If it is suspected that the seal has been broken or if the window breaks, call your local Thorlabs office or distributor. Do not apply power to the camera. Moisture will have been introduced into the chamber, and cooling in the presence of moisture will cause condensation and frost on the CCD, which can damage the entire cooling unit and/or CCD.
Re-examine once again and repeat the process once, if necessary. If contamination continues to be a problem, please call Thorlabs for assistance. CAUTION Ethyl and isopropyl alcohols are highly flammable! Do not use near extreme heat, arcing electrical equipment (such as space heaters) or open flame! Use only with proper ventilation.
Due to the sensitive nature of the no face plate sensor, the wedged window should never be removed from the camera. Please contact Thorlabs for assistance If contamination continues to be a problem, please call Thorlabs for assistance. CAUTION Ethyl and isopropyl alcohols are highly flammable! Do not use near extreme heat, arcing electrical equipment (such as space heaters) or open flame! Use only with proper ventilation.
18.1. Waste Treatment is Your Own Responsibility If you do not return an “end of life” unit to Thorlabs, you must hand it to a company specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.
Scientific Grade Digital Camera Chapter 18: Regulatory 18.3. Certifications and Compliance – CE Declaration of Conformity ITN000081-D02 Rev. V 2/27/2020 Page 59...
Page 65
Scientific Grade Digital Camera Chapter 18: Regulatory ITN000081-D02 Rev. V 2/27/2020 Page 60...
Page 66
Scientific Grade Digital Camera Chapter 18: Regulatory ITN000081-D02 Rev. V 2/27/2020 Page 61...
Page 67
Scientific Grade Digital Camera Chapter 18: Regulatory ITN000081-D02 Rev. V 2/27/2020 Page 62...
Scientific Grade Digital Camera Chapter 18: Regulatory 18.4. FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Chapter 19 Warranty 19.1. General Product Warranty Thorlabs warrants that all products sold will be free from defects in material and workmanship, and will conform to the published specifications under normal use, when correctly installed and maintained. 19.2. Specific Warranties and Repairs All specific warranty and repair information can be found in the general terms and condition located at https://www.thorlabs.com/Images/PDF/LG-PO-001_Thorlabs_terms_and_%20agreements.pdf...
Page 70
Scientific Grade Digital Camera Chapter 20: Thorlabs Worldwide Contacts Chapter 20 Thorlabs Worldwide Contacts www.thorlabs.com/contact For technical support or sales inquiries, please visit us at for our most up-to- date contact information. ITN000081-D02 Rev. V 2/27/2020 Page 65...
Need help?