Help in the event of faults

8
Help in the event of faults
8�1 What to do in the event of faults
8�2 Fixing faults
Fault
Potential malfunctions
The VOGT
The piston has begun to
compressed
rust inside the housing
air device is
due to insufficient oiling.
not working
or is not
powerful
enough.
Too much lubricating
oil used or water in the
rammer.
Subject to change without notice
34
Faults of any kind must be fixed immediately to prevent major damage to
the VOGT compressed air device.
If a fault occurs, disconnect the VOGT compressed air device from the
compressed air supply immediately. Check once again that the device is
depressurized before troubleshooting.
How to fix
Push the piston through the chisel holder using a
suitable punch.
Pour a little VOGT Special Oil (Z 500) into the con-
necting hose and the tool holder.
Briefly operate the device without a tool.
Disconnect the compressed air infeed again.
Pull the infeed hose off again.
Repeat the entire process a few times.
ton
Pour a little (1 to 2 cm³) VOGT cleaner (861 015) into
the connecting hose.
Briefly operate the device without a tool.
Catch the oil/water/detergent mixture that escapes
in a suitable container.
Disconnect the compressed air infeed again.
Pull the infeed hose off again.
Repeat the entire process two or three times.
Pour a little VOGT Special Oil (Z 500) into the con-
necting hose.
Operate the compressed air device.
Dispose of the oil/water mixture in accordance with
the regulations.