Program Function Mode; Program Control - Fluke 9116A User Manual

Table of Contents

Advertisement

6.5.4

Program Function Mode

The next parameter is the program function or cycle mode. There are four pos-
sible modes that determine whether the program scans up (from set-point 1 to
n) only or both up and down (from set-point n to 1), and also whether the pro-
gram stops after one cycle or repeats the cycle indefinitely. Table 2 below
shows the action of each of the four program mode settings.
Pf=1
Use the "UP" or "DOWN" buttons to change the mode.
Pf=4
Press "SET" to continue.
S
Table 2. Program mode setting actions
Function
1
2
3
4
6.5.5

Program Control

The final parameter in the program menu is the control parameter. There are
three choices to choose from 1) start the program from the beginning, 2) con-
tinue the program from where it was when it was stopped, or 3) stop the
program.
Pr=off
Use the "UP" or "DOWN" buttons to change the status.
Pr=StArt
Press "SET" to activate the new program control command and return to the
temperature display.
S
Program mode
New mode
Save new setting
Action
up-stop
up-down-stop
up-repeat
up-down-repeat
Program presently off
Start cycle from beginning
Activate new command
6 Controller Operation
Ramp and Soak Program Menu