Procedures For Daily Inspections - Takara Belmont RS III Operating Manual

Hide thumbs Also See for RS III:
Table of Contents

Advertisement

Procedures for Daily Inspections

To ensure that this product can be used for a long period of time, conduct the inspections below.
Inspection item
Is the plating of the
water control knob
peeled off?
Has the neck cushion
degraded?
Is the mounting surface
of the basin unit wet
with water?
Is there an abnormal
odor coming from the
basin drain?
Does the water control
knob work properly?
Is water output from
the shower head
properly?
Does the basin,
backrest or seat rattle?
Can the basin be filled
with water?
Inspection method
Visually check the water control
knob for flaws, cracks, or peeling
of the plated surface.
During operation or maintenance,
check that there are no burrs or
irregularities on the surface.
Check that there is no tearing, dirt
or sinking of the neck cushion
surface.
Open the maintenance cover and
check that the mounting surface
and pipes are not wet with water.
Check if there is an abnormal odor
coming from the basin drain
Turn the water control knob and
check if warm water is output
properly and that there is no
abnormal noise, then close the
water control knob and check that
warm water stops properly.
Feed the hot water, and visually
check that water is discharged
normally from the showerhead.
Slowly push the rear end of the basin,
top of the backrest or the front end of
the seat in each direction, and check
whether they rattle.
Check that the drain cap can be
used to block the drain and that
water filling the basin does not
drain.
Inspect the product every day
If the inspection results show defects
Flaws, cracks, or peeling of the plated surface
may result in injury of hand. If they exist,
replacement of the knob is required. Contact
your closest dealer.
These may cause pain or transfer dirt to the
customer's neck and head. The neck cushion is
consumable supplies. Replace it as soon as
possible.
There is a possibility that water is leaking from the
pipes. If this is the case, immediately stop using
the product and contact your closest dealer.
Remove any hair and other objects trapped in the
hair catcher. (see page 16)
If there is abnormal noise or the water does not
turn off properly when the water cotrol knob is
closed firmly, there may be a malfunction of the
fauset.
If hot water is not fed normally, clean the strainer
(see pages 18 and 19) and the inside of the
showerhead. (See pages 17.)
If the hot water is turbid, there is a possibility that
the strainer of the check valve is contaminated.
Clean the strainer. (See pages 18 and 19.)
Rattling may cause incorrect operation or damage
in the main body, or cause it to fall over. Stop
using the product.
When the water decreases quickly, there is a
possibility that the drain cap gasket has
deteriorated. The drain cap gasket is a
consumable part. Immediately replace it. (See
page 17.)