Photon Focus MV8-D8424-G01-GT User Manual page 85

Cmos camera series with gige interface
Hide thumbs Also See for MV8-D8424-G01-GT:
Table of Contents

Advertisement

Start pixel index
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
64
68
72
76
80
84
88
92
96
100
Table 11.3: Assignment of status line fields
MAN094 03/2021 V1.0
Parameter width [bit]
32
32
32
32
32
32
32
32
32
24
24
32
12
12
12
12
12
2
12
16
4
16
32
32
32
32
11.9 Status Line and Image Information
Parameter Description
Preamble: 0x66BB00FF
Counter 0 Value (see Section 5.1)
Counter 1 Value (see Section 5.1)
Counter 2 Value (see Section 5.1)
Counter 3 Value (see Section 5.1)
Timer 0 Value in units of clock cycles (see Section
5.2)
Timer 1 Value in units of clock cycles (see Section
5.2)
Timer 2 Value in units of clock cycles (see Section
5.2)
Timer 3 Value in units of clock cycles (see Section
5.2)
Integration Time in units of clock cycles
Reserved
Timer and Integration Time Clock Frequency
Image Average Value("raw" data without taking
in account gain settings) (see Section 11.9.1)
Horizontal start position of ROI (OffsetX)
Image Width
Vertical start position of ROI (OffsetY).In
MROI-mode this parameter is the start position
of the first ROI.
Image Height
Digital Gain
Digital Offset
FineGain. This is fixed a point value in the
format: 4 digits integer value, 12 digits
fractional value.
Line Input Level of LineIn0, LineIn1, LineIn2 and
LineIn3
Camera Type Code (see Table 11.4)
Camera Serial Number
Custom value 0: value of register
StatusLineCustomValue0 that can be set by the
user
Custom value 1: value of register
StatusLineCustomValue1 that can be set by the
user
Encoder 0 Position (see Chapter 6)
85 of 139

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Mv8-d8424c-g01-gt

Table of Contents