Figure 11.2: Commonly used LUT transfer curves
300
250
200
150
100
50
0
0
Figure 11.3: Applying a linear gain with clamping to an image
MAN094 03/2021 V1.0
y = f ( x )
y
m a x
d
Grey level transformation − Gain: y = (255/1023) ⋅ a ⋅ x
200
400
x: grey level input value (10 bit) [DN]
11.5 Grey Level Transformation (LUT)
c
b
=
x
x
0
1
600
800
x
x
m a x
a = 1.0
a = 2.0
a = 3.0
a = 4.0
1000
1200
73 of 139