SPLITMUX Quad Screen Video Splitter
RS232
Serial Port
CPU
RJ45
TO DB9
SERIAL
ADAPTER
CAT5 CABLE
RS232
NTI
SWITCH
First Unit
Figure 35- RS232 connection with Matrix-Y-1 cable
Wiring Schematic of Matrix-Y-1 cable
9D Male
(Unit #1)
2
3
5
RS232 Command Protocol
CPU controller commands supported by the unit are defined below. All commands must be terminated with a <CR> (carriage
return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the
Command Definitions table (below). All characters in the command string are case sensitive (see Command Definitions table),
and all numbers below 10 must have a leading 0 (ex: 1 = 01).
Legend:
(All numbers must be two digits)
SA
:
Serial Address (01-15)
BR
:
Baud Rate Code
IP
:
Input Port (01-04)
Matrix-Y-1
Matrix-Y-1
RJ45
TO DB9
SERIAL
ADAPTER
CAT5 CABLE
RS232
NTI
SWITCH
Second Unit
9D Female
(Source)
3
5
2
7
Jumper
8
1
4
Jumpers
6
Figure 36- Pinout of Matrix-Y-1 cable
OP
<CR>
mode
nn
Matrix-Y-1
Note: The maximum combined
RS232 cable length between the
RJ45
CPU and any NTI switch cannot
TO DB9
exceed 50 feet.
SERIAL
ADAPTER
CAT5 CABLE
RS232
NTI
SWITCH
Last Unit
9D Male
(Unit #2)
3
Not connected to
source connector
5
2
:
Output Port
:
Carriage Return (Hex 0xD)
:
01 = FULL, 02 = QUAD, 03 = PIP, 04 = CUSTOM
:
Layout number to be loaded (01-10)
38
Need help?