Scope Of Delivery; Additional Information; Specialist Installer Qualifications; Intended Use - Maico ER-AP Installation And Operating Instructions Manual

Surface-mounted exhaust air system for single-duct air extraction according to din 18017-3
Table of Contents

Advertisement

1 Scope of delivery

1
Cover
2
G2 air filter
3
Upper part of housing
4
ER EC fan insert
5
Sensor (H or F model)
6
Lower part of housing
7
Cable grommet
8
Housing floor seal
9
Electronic circuit boards
10.1
Metal exhaust socket with tab
10.2
Metal shut-off shutter with release
mechanism
10.3
Fixing screw, to be provided by the
customer
11
ER-AP: Plastic shutter without fire
protection
11.1
Plastic exhaust socket
11.2
Plastic backflow preventer
D
Production date
S1
Rating plate
S2
TÜV sticker stating "Slide in blower
unit in parallel"
T
Time strip
1 Scope of delivery
ER-AP surface-mounted housing
• Surface-mounted housing with plastic shut-off
device for connection to the DN 75/DN 80 ex-
haust air duct.
ER-APB surface-mounted housing
• Surface-mounted housing with provided fire
protection shut-off device for connection to the
DN 75/DN 80 exhaust air duct.
Other components
• Air filter
• TimeStrip on title page of these instructions
• Installation and operating instructions

2 Additional information

Go directly to the product with a smartphone. On-
line at www.maico-ventilatoren.com
4
ER-APB

3 Specialist installer qualifications

Installation may only be carried out by trained
specialists who have the necessary knowledge
and experience in ventilation engineering. The
unit must be connected in accordance with the
national technical approval.
Only a qualified electrician is permitted to work
on the electrics. You are deemed a qualified elec-
trician if you are familiar with the relevant stand-
ards and guidelines, can competently and safely
connect units to an electrical power supply in line
with the Wiring diagrams [} 24] and are able to
recognise and avoid risks and dangers associ-
ated with electricity on the basis of your technical
training and experience.

4 Intended use

These fans are used to extract air from interior
bathrooms and toilet rooms, storage rooms and
kitchens with an outside window.
If operated other than stated in DIN 18017-3, the
fans may also be used as standalone units (fitted
on the wall or ceiling) or to extract air from other
rooms (interior kitchen etc.).
The fans are only intended for domestic use and
similar purposes.
5 Safety instructions and warn-
ings
DANGER
Indicates a possibly hazardous situation which
will result in death or serious injuries if not
avoided.
WARNING
Indicates a possibly hazardous situation which
could result in death or serious injuries if not
avoided.
CAUTION
Indicates a possibly hazardous situation, which
could result in minor to moderate injuries.
NOTICE
Indicates a possible situation, which could cause
damage to the product or its surroundings.
ER-AP