Permitted Exhaust Air Systems; Unit Versions; Product Features - Maico ER-AP Installation And Operating Instructions Manual

Surface-mounted exhaust air system for single-duct air extraction according to din 18017-3
Table of Contents

Advertisement

• ER-AP/ER-APB fans can also be used as stan-
dalone units.
• Installation in the wall or ceiling is permitted.
• They can also be used to extract air from an-
other room, for example an interior kitchen.

7.3 Permitted exhaust air systems

Exhaust air system
PAM-GLOBAL RML cast
ventilation system *
Ceiling barrier system **
System with fire-proof
shaft *
Air extraction system
without fire protection **

7.4 Unit versions

Unit type
Circuit board
ER AP 60,
Standard [9.1]
ER APB 60
ER AP 100,
Standard [9.1]
ER APB 10
ER AP 60 VZ,
VZ circuit board
ER APB 60 VZ,
ER AP 100 VZ,
ER APB 100 VZ
ER AP 60 F,
F circuit board
ER APB 60 F,
ER AP 100 F,
ER APB 100 F
ER AP 60 G,
ER APB 60 G,
ER AP 100 G,
ER APB 100 G
ER AP 60 H,
ER AP 60 H,
ER AP 100 H,
ER APB 100 H
Tolerance of all time details max. + 20 %.
• ER-APB: Fire protection model with mainten-
ance-free fire protection shut-off device
K 90-18017 (metal backflow preventer with
soldered strut).
• ER-AP: Model without fire protection. With
maintenance-free plastic backflow preventer.
ER-APB
ER-AP
yes
no
yes
yes
Start delay [s]
type
50
[9.5]
50
[9.4]
G board
[9.2]
H board
[9.3]
* ER-APB can be used
• on the shaft, connection duct made of flexible
aluminium duct;
• outside the shaft, connection duct made of steel
folded spiral-seams duct.
** ER-AP can be used on the shaft or outside the
shaft, connection duct made of flexible aluminium
duct.
no
yes
no
yes
Overrun time
[min]
6
6
>6

7.4.1 Product features

• DN 80 exhaust socket
• Control circuit board in fan insert
• Electrical plug connection for quick fan insert in-
stallation in the lower part of the housing. Fan
insert secured with snap-fit fasteners.
• Upper part of housing with exhaust air filter.
Trouble-free filter change without tools possible.
7 System and product information
speed control-
lable
no
yes
no
no
no
no
Mains cable
[mm"]
3 x 1.5
3 x 1.5
5 x 1.5
3 x 1.5
5 x 1.5
5 x 1.5
9

Advertisement

Table of Contents
loading

Table of Contents