Maico AP 100 Installation And Operating Instructions Manual

Maico AP 100 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Quick Links

AP 100/100 B/120/150
SG 100/100 B/120/15
VENTILATOREN
Montage- und Betriebsanleitung
Installation and operating instructions
Instructions de montage et mode
d'emploi
Maico Elektroapparate-Fabrik GmbH
Steinbeisstr. 20
78056 Villingen-Schwenningen
Germany
www.maico-ventilatoren.com
Mail: info@maico.de
Service: +49 7720 6940
Ersatzteile:
www.shop.maico-ventilatoren.com
DE
UK
FR

Advertisement

Table of Contents
loading

Summary of Contents for Maico AP 100

  • Page 1 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Montage- und Betriebsanleitung Installation and operating instructions Instructions de montage et mode d’emploi Maico Elektroapparate-Fabrik GmbH Steinbeisstr. 20 78056 Villingen-Schwenningen Germany www.maico-ventilatoren.com Mail: info@maico.de Service: +49 7720 6940 Ersatzteile: www.shop.maico-ventilatoren.com...
  • Page 2 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Abmessungen / Dimensions [mm] AP 100/AP 100 B/SG 100/SG 100 B A=150, B=98, C=29, D=21 AP 120/SG 120 A=172, B=118, C=30, D=23 AP 150/SG 15...
  • Page 3 Anleitung komplett lesen. Sicherheitshinweise beachten. 1 Lieferumfang Verschlussklappe/Außengitter, Dichtband, AP 150/SG 15 mit Fliegengitter, diese Montage- und Betriebsanleitung. Fliegengitter für AP 100/100 B/120 und SG 100/100 B/120 optional. 2 Bestimmungsgemäße Verwendung Selbsttätige Verschlussklappen AP... und festste- hende Außengitter SG... werden als Abschluss- elemente von Lüftungsleitungen (zentrale/de-...
  • Page 4 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Zulässig ist der Einsatz nur: ● in Kombination mit der Wandhülse WH... ● bei senkrechter Einbaulage. ● bei Festinstallation Aufputz an einer Außen- wand mit ausreichender Tragkraft. ● bei Montage mit geeignetem Befestigungs- material (bauseitig bereitzustellen).
  • Page 5 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN hütungsvorschriften beachten. Maßnahmen des Arbeitsschutzes und der Arbeitssicherheit beachten: Intakte Schutzkleidung etc. Nicht zulässiger Betrieb AP-Verschlussklappen/SG-Außengitter dürfen in folgenden Situationen auf keinen Fall einge- setzt werden. ● In explosionsfähiger Atmosphäre. ● bei Entzündungs-/Brandgefahr durch brenn- bare Materialien, Flüssigkeiten oder Gase.
  • Page 6 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Arbeiten sicher erkennen und vermeiden können. ● Verletzungsgefahr bei Arbeiten in der Höhe. Benutzen Sie geeignete Aufstiegshilfen (Lei- tern). Die Standsicherheit ist zu gewährleis- ten, die Leiter ist ggf. durch eine 2. Person zu sichern.
  • Page 7: Montage

    AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN 5 Technische Daten ● Gewicht 0,1 bis 0,4 kg ● Druckverlust 10 Pa ● Schutzart (EN 60529) IP 20 6 Montage Vor der Montage die zur AP-Verschlussklappe/ zum SG-Außengitter passende Wandhülse WH 100, WH 120 oder WH 150 in der Außen- wand anbringen.
  • Page 8 Flansch in die Wandhülse schieben und mit 4 Schrauben an der Wand fest- schrauben. Auf korrekte Lage des Dichtban- des achten. Einbaulage mit Maico-Schrift- zug rechts unten beachten. 6. AP/SG 100/100 B/120: Ggf. optionales Fliegengitter FG in die Verschlussklappe/das Außengitter einlegen.
  • Page 9 9 Entsorgung Verpackungsmaterialien und Altprodukte sind nach deren Nutzungsende umweltgerecht nach den in Ihrem Land geltenden Bestimmungen zu entsorgen. Altprodukte auf keinen Fall mit dem normalen Hausmüll entsorgen. Impressum: © Maico Elektroapparate-Fabrik GmbH. Deutsche Originalanleitung. Druckfehler, Irrtümer und technische Änderungen vorbehalten.
  • Page 10: Observe Safety Instructions

    1 Scope of delivery Shutter/external grille, sealing strip, AP 150/ SG 15 with fly screen, these installation and op- erating instructions. Fly screen for AP 100/100 B/120 and SG 100/100 B/120 optional. 2 Intended use AP... airstream-operated shutters and SG... fixed...
  • Page 11 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Operation is only permitted: ● in combination with the wall sleeve WH...; ● with a vertical installation position; ● with fixed installation, surface-mounted on an external wall with sufficient load-bearing capacity; ● when installed with suitable mounting mate- rial (to be provided by the customer);...
  • Page 12 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Observe occupational health and safety meas- ures: protective clothing in good repair etc. Impermissible operation AP shutters/SG external grilles also must not be used under any circumstances in the following situations: ● in potentially explosive atmospheres;...
  • Page 13: Ambient Conditions

    AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN ● Risk of injury when working at heights. Use appropriate climbing aids (ladders). Stability should be ensured, if necessary have the ladders steadied by a 2nd person. Ensure that you are standing securely and cannot lose your balance and that there is no one under the shutter/the external grille.
  • Page 14: Installation

    AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN 5 Technical data ● Weight 0.1 to 0.4 kg ● Pressure loss 10 Pa ● Degree of protection (EN 60529) IP 20 6 Installation Before the installation, install the wall sleeve, which matches the AP shutter/the SG external grille (WH 100, WH 120 or WH 150), in the outer wall.
  • Page 15 4 screws. Ensure the correct position of the sealing strip. Note the installation position: with Maico letter- ing on the bottom right. 6. AP/SG 100/100 B/120: If necessary, insert optional fly screen FG into the shutter/the external grille.
  • Page 16 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN Notice for the AP...: Do not open, close or bend the lamellae too much (lamellae breakage). NOTICE: Clean the AP shutter/SG external grille only with water and not in the dishwasher. Do not use aggressive, harmful or easily flammable cleaning agents.
  • Page 17: Volume De Fourniture

    Volet de fermeture / grille extérieure, ruban isolant, AP 150/SG 15 avec moustiquaire, cette notice de montage et ce mode d’emploi. Moustiquaire pour AP 100/100 B/120 et SG 100/100 B/120 en option. 2 Utilisation conforme Les volets de fermeture automatiques AP... et les grilles extérieures fixées SG...
  • Page 18 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN SG servent de protection anti-intempéries. Les volets de fermeture AP sont aussi utilisés comme dispositif de blocage de l’air froid. L’utilisation est uniquement autorisée : ● en combinaison avec la gaine murale WH...
  • Page 19 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN 3 CONSIGNES DE SÉCURITÉ Le montage des volets de fermetures AP / grilles extérieures SG exclusivement réservé aux installateurs spécialisés en technique de ventilation. Condition préalable : formation professionnelle et connaissance des normes techniques, des directives et ordonnances de l’UE.
  • Page 20 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN liquides ou gaz combustibles risquant de s’enflammer sous l’effet de la chaleur ou d’étincelles et de provoquer un incendie. Consignes de sécurité générales ● Danger pour les non professionnels, les enfants et les personnes ayant des capacités physiques, sensorielles ou psychiques réduites ou sans connaissances suffisantes.
  • Page 21: Conditions Ambiantes

    AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN ● Les modifications et transformations appor- tées sur le volet de fermeture AP / la grille extérieure SG sont rigoureusement interdites et dégagent le fabricant de toute responsabi- lité ou garantie. ● Manipuler les matériaux d’emballage avec prudence.
  • Page 22 5. Introduire les volets de fermeture AP / grilles extérieures SG avec la bride dans la gaine murale et fixer sur le mur avec 4 vis. Veiller à la position correcte du ruban isolant. Respecter la position d’installation avec logo Maico en bas à droite.
  • Page 23 AP 100/100 B/120/150 SG 100/100 B/120/15 VENTILATOREN 6. AP/SG 100/100 B/120 : le cas échéant, insé- rer une moustiquaire FG optionnelle dans le volet de fermeture / la grille extérieure. 7. AP/SG 100/100 B/120 : enfoncer l’unité de boîtier dans le logement jusqu’à ce qu’elle s’encliquette de manière audible dans les 4...
  • Page 24 Ne jeter en aucun cas le produit usagé avec les ordures ména- gères normales. Mentions légales : © Maico Elektroapparate-Fabrik GmbH. Traduction de la notice allemande d'origine. Sous réserve de fautes d'impression, d'erreurs et de modifications techniques.

This manual is also suitable for:

Ap 100 bAp 120Ap 150Sg 100Sg 100 bSg 120 ... Show all

Table of Contents