12.4.3 Device access locks
Access to the parameters can be controlled with the Device access locks parameter.
Index Sub-
Off-
Access
Index
set
Rights
0x0C
1
0
R/W
2
1
R/W
3
2
R/W
4
3
R/W
Description of parameter values
Index name
Device access locks
Local user interface
Local parameterization
Local user interface
12.4.4 Profile Characteristics
The Profile Characteristics parameter specifies which DeviceProfileIDs, CommonApplicationProfileIDs and FunctionClassIDs
are supported.
Index Sub-
Off-
Access
Index
set
Rights
0x0D
0
0
RO
Description of parameter values
Index name
Profile Characteristics
www.gemu-group.com
Length
Index name
1 bit
Device access locks Parameter (write) ac-
1 bit
1 bit
1 bit
Parameter
Values
0
1
Data storage
0
1
0
1
0
1
Length
Index name
8 bytes
Profile
Characteristics
Parameter
Values
0x8000
0x8002
0x8003
0x8100
Parameter
BooleanT
cess
Data storage
BooleanT
Local parameteriza-
BooleanT
tion
Local user interface
BooleanT
Enable write access
Block write access
Enable storage of parameter data in the IO-Link master
Block storage of parameter data in the IO-Link master
Enable local parameterization
Block local parameterization
Enable local user interface
Block local user interface
Parameter
Device identification objects
Process data mapping
Diagnostics
External identification