Sync output
(open termination)
Communication
interface
Power
Lens Mount
Flange back
Optical axis
Operating
temperature
/Humidity
Storage temperature
/humidity
Vibration
Shock
Regulation
Dimensions
Weight
Connectors
Note 1: This is maximum accumulation time at minimum line cycle ( 52. 5μs)
Note 2: LSB numbers shown in parenthesis is for 8 bit output.
Note 3: This is effective only when specified connector or cable is used.
Refer to chapter 5. Connectors.
CV-L107CL
Camera link LVAL, DVAL, EEN
Hirose 12Pin XEEN (Negative logic) 4.0 Vp-p (no termination)
Via Camera Link connector or RS-232C (Hirose 12-Pin connector)
Baud rate : 9600bps
Interface is switched by SW1 located rear panel.
Camera Link and Hirose 12P can not be used at the same time.
DC +12V±10% 1100mA (max 1200mA)
Note: Use a power supply capable of providing more than 3A.
Nikon F-Mount or P-Mount(M42x1)
F-mount is standard and P mount is an option
Maximum allowed rear protrusion on lenses:
Nikon F-Mount: 13 mm
P-Mount (M42x1): 12 mm
Nikon F-Mount : 46.5mm tolerance: 0 ~ -0.05mm
Universal P-Mount : 45.5mm tolerance : 0 ~ -0.05mm
Center ±0.1mm(Max)
- 5C to +45C / 20 to80% ( non-condensing)
-25C to +60C, 20 to 80% ( non-condensing)
3G (20Hz to 200Hz XYZ direction)
50G
CE (EN61000-2+EN61000-3)
IEC61000-4-2 Conforming to Level 4
FCC Part15 Class B
RoHS
90(W) x 90(H) x 90(D) mm (without connector and lens mount
protrusion)
830 g (Both F-Mount and P-Mount)
Camera Link : 10226-1A10JL x2
Hirose 12Pin : HR10A-10R-12PB
(Note 3)
45