VDS2064(L) / VDS3104(L)

Figure 3-3 Ports of the Oscilloscope (take VDS3104(L) for instance)
1. Probe Compensation: Measurement signal (3.3 V/1 kHz) output
2. MULTI Connector (optional): Connect Q9 cable with the MULTI port
3. MULTI port: EXT trigger input, trigger output or Pass/Fail output
4. LAN port (optional): Network port which can be used to connect with PC
5. USB port: Supply power by PC USB or the adapter; communicate with PC
6. Signal input of Channel 4
7. Signal input of Channel 3
8. Signal input of Channel 2
9. Signal input of Channel 1
Note: If you use LAN port to communicate with PC, the oscilloscope should be
powered by the adapter.