3-7 LED indication mode :
3-7-1 Show Switch State:When switch is on, LED is on. When switch is off, LED is
off. The default setting is Show Switch State.
3-7-2 Show Night mode:When switch is on, LED is off. When switch is off, LED is
on.
3-8 Auto off timer:
Whenever PAN15 switches to on, the auto off timer begin to count down. After the
timer decrease to zero, it will switch to off automatically. However if Auto off timer
is set as 0, the auto off function will be disabled. The default setting is 0.
3-9 RF off command mode
Whenever a switch off command, BASIC_SET、BINARY_SWITCH_SET、
SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.
3-9-1 Switch Off:It switches to OFF state. The default setting is Switch Off.
3-9-2 Ignore:The switch off command will be ignored.
3-9-3 Switch Toggle:It switches to the inverse of current state.
3-9-4 Switch On:It switches to ON state.
3-10 Switch status report mode:
Whenever the status of switches changes, it will send a Binary Switch report to the
group1 node. The default setting is 1 (Enable).
4. Protection Command Classes
PAN15 supports Protection Command Class version 2, it can protect the switch
against unintentionally control by e.g. a child. And it can also protect the switch from
being turned off by setting it in "No RF Control" state.
After being set to "Protection by sequence" state, any intentional pressing of On/Off
button should be hold longer than 1 second, or the switch state will not change.
However, the operation of learn function does not change, because learning will not
be protected.
5. Firmware update over the air (OTA)
PAN15 is based on 500 series SoC and supports Firmware Update Command Class,
it can receives the updated firmware image sent by controller via the Z-wave RF
media. It is a helpful and convenient way to improve some function if needed.
6. Command Classes
The Switch supports Command Classes including...
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_ALL
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_PROTECTION
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

Troubleshooting

Symptom
Cause of Failure
The Switch not working and
1. The Switch is not
LED off
plugged into the
electrical outlet
properly
2. The Switch break down
The Switch LED
1.Check if the load
illuminating, but cannot
plugged into the Switch
control the ON/OFF
has its own ON/OFF
Switch of the load attached
switch
6
Recommendation
7.
Check power connections
2. Don't open up the Switch and send it
for repair.
1. Set the ON/OFF switch of the load
attached to ON
2. Unprotected the switch or follow the
instruction of protection.