Quick Troubleshooting; Configuration Parameters - Philio PHI PST02-1B Quick Start Manual

Z-wave 3 in 1 sensor (motion, illumination, temperature)
Hide thumbs Also See for PHI PST02-1B:
Table of Contents

Advertisement

3. Node ID has been excluded.
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities.
The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network
operations to send out a Node Information Frame. To issue a NIF execute the following action: Press any key once, the device will awake 10 seconds.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order
to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and
store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life
time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the
mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a
static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the
desired responses of the device. To wakeup the device please perform the following action:
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing
Firmware-Update over the Air
This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller
starts the update process, perform the following action to confirm the firmware update: The device support the Z-Wave firmware update via OTA. Before
starting the procedure, please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update
mode, and then press the front tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that
time, please don"t remove the battery, otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is
recommended that the user power up the device. Caution: After remove the battery, please wait about 30
seconds, and then re-install the battery.
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a
different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups
and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective
association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
2

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock
further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be
the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte
value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 2: Basic Set Level
Setting the BASIC command value to turn on the light
Size: 1 Byte, Default Value: 255
Setting
0
1 - 100
254
Parameter 3: PIR Sensitivity
PIR sensitivity settings.
Size: 1 Byte, Default Value: 80
Maximum Nodes
Description
8
Receiving the report message, like triggered event, temperature, illumination etc.
8
Light control, the device will send the "Basic Set" command
Description
turn off the light
the light strength.
turn on the light.
Press any key once, the device will awake 10 seconds.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents