Example:
Scale = 0x02 (W)
Precision = 1
Size = 4 Bytes (W)
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
2-2-2 Accumulated Power Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]
Meter Report Command: [Command Class Meter, , , , Meter Report, , , , Rate Type =
0x01 , , , , Meter Type = 0x01 , , , , Precision = 2 , , , , Scale = 0 , , , , Size = 4 , , , , Meter Value(KWh)]
Example:
Scale = 0x00 (KWh)
Precision = 2
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(KWh)
Meter Value 2 = 0x01(KWh)
Meter Value 3 = 0x38(KWh)
Meter Value 4 = 0xA3(KWh)
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter
Value 3*256) + (Meter Value 4) = 800.35 (KW/h)
2-2-3 Clearing accumulated power consumption
Meter Reset Command: [Command Class Meter, Meter Reset]
2-2-4 AC load Voltage (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
Meter Report Command:
[Command Class Meter, , , , Meter Report, , , , Rate Type = 0x01, , , , Meter Type = 0x01, , , ,
Precision = 1, , , , Scale = 4, , , , Size = 2, , , , Meter Value(V)]
Example:
Scale = 0x04 (V)
Precision = 1
Size = 2 Bytes (V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
2-2-5 AC load current ( I )
When receiving Meter Get Command, it will report Meter Report Command to the
node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Report Command:
[Command Class Meter, , , , Meter Report, , , , Rate Type = 0x01, , , , Meter Type = 0x01, , , ,
Precision = 2, , , , Scale = 5, , , , Size = 2, , , , Meter Value(I I I I )]
Example:
Scale = 0x05 (I)
Precision = 2
Size = 2 Bytes (I)
Meter Value 1 = 0x01(I)
Meter Value 2 = 0x21(I)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
2-2-6 load power factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
node.