Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
Meter Report Command:
[Command Class Meter, , , , Meter Report, , , , Rate Type = 0x01, , , , Meter Type = 0x01, , , ,
Precision = 2, , , , Scale = 6, , , , Size = 1, , , , Meter Value(PF)
Example:
Scale = 0x06 (PF)
Precision = 2
Size = 1 (PF)
Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
3. Z-Wave's Configuration
Configuration
Function
Size
Parameter
(Byte)
1
Watt Meter
2
Report Period
2
KWH Meter
2
Report Period
Threshold of
3
2
current for Load
caution
Threshold of
4
2
KWh for Load
caution
Restore switch
5
1
state mode
Mode of Switch
6
1
Off function
LED indication
7
1
mode
Auto off timer
8
2
RF off
9
1
command mode
Switch Status
11
1
Report mode
Value
Unit
Default
Description
0x01-
5s
720
720*5s=3600s=1 hour
0x7FFF
0x01-
10min
6
6*10min=1 hour
0x7FFF
0.01A
10-1300
1300
1300*0.01A = 13A
1KWh
1-10000
10000
0-2
1
0 : Switch off
1 : Last switch state
2 : Switch on
0-1
1
0 : Disable
1 : Enable
1-2
1
1 : Show switch state
2 : Show night mode
1s
0-0x7FFF
0
0 : Disable auto off
function
1-0x7FFF : 1s ~ 32767s
0-3
0
0 : Switch off
1 : Ignore
2 : Switch toggle
3 : Switch on
0-1
1
0 : Disable
1 : Enable
Watt
3-1
Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN15 will report its
instant power consumption every 1 hour to Group1 node. The maximum interval
to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN15 will report its
Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55
days (10min*32767/1440=227.55 days).
3-3 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 1300, when the load current of Relay1 over this value, PAN15
will send current meter report to warn the Group1 node, the Range of the setting
value is from 10 to 1300,and the default value is 1300.
3-4 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 over
this value, PAN15 will send KWH meter report to warn the Group1 node,
minimum value is 1KWh and default value is 10000 kWh.
3-5 Restore switch state mode :
Whenever the AC power return from lost, PAN15 will restore the switch state which
could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting
is LAST SWITCH STATE.
3-6 Mode of switch off function :
When the mode of switch On/Off is set to 0, any command of switch off will be
disabled and the On/Off function of include button will be disabled. The default
setting is enable mode.